KE-350 Installation and Operations Manual
Preparing for Installation
System Components
There are four primary components and one optional component to be installed:
1. The Keypad should be
mounted on the wall adjacent
to the door. It should be on
the same side as the door
strike and about 4 feet above
the floor.
2. The Control Module should
be mounted inside the
building near a power source.
Typically the control module
is hidden in a false ceiling or
closet. The control module
must be located in an
environmentally controlled
area where the temperature
remains between – 40
°
C and
+49
°
C (-40
°
F and 125
°
F.)
3. The Wiring Cable connects the keypad to the control module. It is important not to locate
the cable adjacent to any wiring that carries line voltage.
Typical Installation
4. The Electric Strike/Other Locking Device(not included) connects to the KE-350’s Main
Relay output via a strike cable (SC). See Appendix A - Typical Wiring Diagrams
5. A Parallel Printer (optional) – connects directly to the KE-350. Although it is not
necessary to have a “dedicated” printer, we suggest connecting a printer cable (PC) to
the KE-350, which leads to a nearby parallel printer. Anytime you need to print anything
from the KE-350, simply connect the printer cable to the printer.
3