For any additional Key module or Add On cabinet it is required to set up the address
on a DIP switches on a back panel of key modules. Left 4 switches set up the cabinet
number and the right switches the module number.
For your convenience flat cables for the Add-On cabinets and control panel are
additionally equipped with the extra sockets male and female. So you could plug and play
add on cabinets in any side.
It is not possible to make a mistake with the sockets all connectors are identical.
1.5.
Connection of control signals
System could trigger up to 5 control signals from Battery module. You could link
those signals to the Building Alarm system or to CCTV systems. Outputs could be
programmed to the different events: alarm, faults, door open, close, key return and
remove and so on.
X1, X2 connectors have 4 solid state relays. Contacts are 250v 100mA 30 Om.
Connectors X1, X2
OUT0
Output 0
OUT0
Output 0
OUT1
Output 1
OUT1
Output 1
OUT2
Output 2
OUT2
Output 2
OUT3
Output 3
OUT3
Output 3
Connector X3(NO/NC relay) 250V 5A