23
EN
parameters
Description
Default min
max
unit
type
1
Deceleration lenght
Determines how far in advance reduced speed is imposed to
the switch's stop.
50
0
200
cm
(step 10)
2
ramp acceleration and deceleration time.
the lower the value, the shorter and sharper is the ramp.
10 (30*)
10
30
3
impact force on obstacle: allows faster reaction time on the
obstacle (e.g. impact in the absence of rubber edge), lower
value = faster reaction time
50
0
100
4
further acceleration at start. useful to speed up the opening
of the barrier.
1
0
1
Ba
5
obstacle/edge reverse time (0 = disabled)
3
0
20
s
sl
6
pedestrian opening lenght
Determines the partial opening of the installation from the
closeD position.
50
0
990
cm
(step 10)
sl
7
pedestrian opening automatic auto-reclosing time
20
0
600
s
(step 10)
sl
8
Photocell F2 configuration
0.
enabled for both opening and closing op/cl
1.
enabled only for opening op
0
0
1
9
enables opening with f1 obscured
1
0
1
10
Man Present configuration (only for open/close inputs)
0.
0. Disabled
1.
1. man present
0
0
1
11
clearance. allows to stop before the fully open position: it is
useful to avoid mechanical stress during opening.
0
0
100
Ba
12
Pre-flashing time
0
0
10
s
13
courtesy light timer
0
0
900
s
(step 10)
14
courtesy
light configuration
1. on if courtesy light timer tcy is not expired
2. on if the gate is not tcy time
1
1
2
15
courtesy litht level at the end of the manouvre (0 = light is off,
other values light will stay on all the time at the desired level)
0
0
100
16
Open gate light configuration
0.
on/off
1.
modulated by the position of the gate
2.
magnetic electric lock function ( interface with a
24V external relay). to activate this function it is
necessary to activate also pre-flashing for 1 sec.
(tpr = 1)
0
0
2
17
cycles before maintenance (0 = disabled). When level set is
reached the next cycles will be done with a fast flashing to
advise the user
0
0
100
1000
cycles
18
Enables the constant flashing of the request for maintenance
(function performed only when the gate is closed)
Under battery back-up flashing will not be performed
0
0
1
19
number of encoder impulses per motor revolution
4
1
16
sl
20
sets default values and type of control
0.
sliding
1.
Barrier
2.
sliding 400 Kg (nep=1*) - lsi blocked at 50
0
0
1
To set the default values: 1) Enter the advanced programming 2) Select the "dEf" parameter 3) Activate the edit mode (displays "0" flashing)
4) Accept the change (press "MEnu" button for 2 seconds). At this point you should see a countdown d80,d79.....d02,d01
The ADVAnCED MEnu allows you to further customize the instal-
lation by changing some parameters not accessible from the basic
menu
To access the ADVAnCED menu, hold down the MEnu button for 5
seconds. To change the parameters of the ADVAnCED MEnu pro-
6 - INsIGhTs - ADVANCED MENU
ceed as indicated for the bASIC MEnu
In the last column are indicated the parameters used only for a
specific type of automation: SL sliding motor, BA barrier, BL over-
head, SE sectional.
* nEP value depends on motor encoder typology.
* Values for 400 Kg sliding motors.