18
EN
4 - prODUCT INsTAllATION
MOTOR COnnECTOR
Terminal block for power connections, for 24Vdc motor and
encoder
M-
Motor power (red or brown)
M+
Motor power (green or white)
GnD
Encoder (white)
EnC
Encoder signal output (green or blue)
+5V
Encoder power; (brown or red)
POWER COnnECTOR
+Vac
Transformer Power 24÷26 Vac (12 A peak)
-Vac
Transformer Power 24÷26 Vac (12 A peak)
Grounding
CR
Courtesy light, +24 V to be connected to "C", 25 W
max
C
Common for outputs "CR" and "LA"
LA
Flashing, +24 V to be connected to "C", 25 W max
-
Common for outputs “+24” and "SCA"
+24
Stabilized output, 24 V, 300 mA max, tolerant to short-
circuit
COMMO
n
3
3 4
1 2
1 2
TX
RX
nC
F2
24Vac/dc
- +
24Vac/dc
- +
3
3 4
1 2
1 2
TX
RX
nC
F1
24Vac/dc
- +
24Vac/dc
- +
+V
ac
-V
ac
CR C LA - +24
SCA CO F2 F1 ST OP CL PE PP C CH2 CH2 A sig A gnd
M-
M+
GnD
EnC
+5V
M
Motor
T2A 230V
230Vac
50/60Hz
n
L
encoder
RG58
Aerial
SW5 SWITCH
Set at "On" disables CO, F2, F1, ST inputs.
Eliminates the need to jump the inputs on terminal block.
WArNING - connected safeties are excluded with
dip switch ON
On
4.1 - electrical connections
WARnInG - before making connections, verify that the installation is not powered
n
C Limit
Switch
n
C Limit
Switch
Summary of Contents for CT-724S