WARNING
Be sure to use shielded wire for signal input and shielding net shall be single-ended grounded.
Be sure to use shielded wire for all control signal connecting lines and shielding net shall be
single-ended grounded.
XI. Motor forward and backward control:
Forward start
Backward start
Forward start: FW and COM shall be shorted connected, i.e. forward run.
Backward start: BW and COM shall be shorted connected, i.e. backward run.
Note:
In case that COM terminal is not shorted connected with FW or BW terminal, driver is inoperative.
In case that COM terminal is shorted connected with FW and BW terminal at the same time, driver
is inoperative.
XII. Brake control:
Brake control
Brake control: STOP and COM terminal shall be shorted connected, i.e. motor will be immediately
stopped.
Note: In case of forward brake, if link between STOP and COM is not disconnected, backward start