Note:
4*Φ5mm mounting hole is equipped on the bottom of driver housing to facilitate horizontal
installation.
This driver shall be kept away from dust, high-humidity environment and accidental contact shall
also be avoided. Enough space shall be reserved around the driver for ventilation and regulation.
When fixed, this driver shall be kept away from other heat source. Guarantee that this drive works
within the range of specified environment temperature. Installed on equipments with intense
vibration is not recommended; if not, please take precautions against vibration.
I. Wiring requirements:
1. Do not connect wire under charged circumstances.
2. Insulated wire and shielded wire matching well with driver’s voltage and current shall be selected
for the device; Specifications of power input line and motor connecting line selected for the driver
are shown in following table:
Table 1 Specification and length of wires
Current (A)
Wire specification (
2
mm
)
Max. length (m)
Power input line:
100
10
15
Motor output line:
100
10
15
WARNING
In any cases, signal line and logic control wire is not allowed to be bound, mixed or wired with
power input wire, output wire (motor wire) and other power lines, induced voltage generated
may cause interface, malfunction or direct damages upon the driver.
3. As driver does not have internal protection of opposite connection, please be sure to guarantee
that positive and negative poles of power input are consistent with that of external power supply,
otherwise, damages may be caused.
4. Please use proper tools for wiring and guarantee its correctness.
VII. Terminal connection diagram: