Page 4
Page 5
Serial IR & IR Emitter Control
½
The “Serial IR” port requires the use of a Male 3.5mm Mono cable (not included) with the IR
command signal being carried on the “Tip” of the input inserted into the KD-HDSW unit. The
location of the IR signal may vary by control system used. Please verify the location of the IR
signal with your control system.
½
When using the IR Emitter / IR Extender (sold separately), the
IR Emitter must be mounted over the IR Sensor on the KD-
HDSW unit. It is recommended that the rear IR sensor of the
KD-HDSW unit be utilized for these applications. One end of
the cable is connected to the IR Receiver / Master Controller
/ IR Extender / IR Connecting Block, while the other end is
mounted over the IR Sensor of the KD-HDSW unit.
RS-232 Commands and Protocol
½
KD-HDSW units are compatible with all Control Systems, such as AMX
®
, Control4
®
, Crestron
®
,
RTI
®
, Universal
®
½
Connect your Control System’s Master Controller to the KD-HDSW unit using the RS-232 port.
Follow all instructions provided with your control system.
½
RS-232 Protocol:
»
Baud Rate = 9600 bits per second
»
Data Bits = 8
»
Parity = None
»
Stop Bits = 1
»
Flow Control = None
RS-232 Command List:
RS-232 Command
Description
Comments
pwr_1
Power On
pwr_0
Power Off
sel_x
x = 1-4, 5, 6
1-4 = Input #, 5 = Up, 6 = Down
asl
Auto Select Enable/
Disable
hep
Help
Full RS-232 command listing
sta
Status
“s1y” y = active input
sir_x_x_y
Addressing per
Command
x x = desired two-digit address for
command (01 – 99)
y = Input Select, Up, Down (1-4, 5, 6)
gir
Address Setting Status
dir_y
Delete Address Setting
per Command
y = Input Select, Up, Down (1-4, 5, 6)
½
All RS-232 commands must be in lower case letters, require spaces where indicated above with
( _ ), and require a carriage return to be sent.
Multiple KD-HDSW Unit Configurations
Up to 99 individually addressable units can be installed. KD-HDSW switchers allow you to assign
a two-digit address to each unit or each of the selectable inputs. This capability can be configured
via IR or the RS-232 port.
½
Addressing Buttons / Units via IR
»
With power enabled on the unit, press the “Power On” button. The “Input Select” LED
lights will begin to blink, indicating that the KD-HDSW unit is ready to receive the address
information.
»
Press the first digit (0 – 9) of the two-digit address. Once this first digit has been received
“Input Select 1” LED will blink.
»
Press the second digit (0 – 9) of the two-digit address. Once this second digit has been
received “Input Select 1” and “Input Select 2” LED’s will blink.
»
Press the Input Select button (Input 1 – Input 4, Up or Down) that you wish to assign the
two-digit address to. Once this is completed, all “Input Select” lights will become solid
indicating that the Input Select button has now been re-addressed.
»
Repeat Steps 2 through 4 if you wish to assign an address to additional “Input Select”
buttons or to your entire KD-HDSW unit.
»
Press “Power On” button to exit addressing mode when completed.
½
Addressing Buttons / Units via RS-232
»
See “RS-232 Commands and Protocol” section for RS-232 Addressing Commands
»
To address an Input, use “sir_x_x_y” command. To address an entire unit, repeat command
for each Input, Up, and Down
»
For address settings, use “gir” RS-232 command to receive a list of address settings
»
To delete address settings, issue “dir_y” RS-232 command
Ground
Signal
KD-HDSW_Series_Manual_2011.indd 4-5
8/2/11 12:44 AM