4
Unit Control Ports
›
MAIN Control Port
»
6-Pin Terminal Block for IR and RS-232
»
RS-232 and TCP/IP commands may be found in the
RS-232 & TCP/IP Commands
section
»
Pin out:
»
Pin 1 = IR Signal
»
Pin 2 = IR Ground
»
Pin 3 = RS-232 Tx Data
»
Pin 4 = RS-232 Ground
»
Ping 5 = RS-232Rx Data
»
Pin 6 = Ground (optional)
›
TCP/IP Control Port
»
Connect an Ethernet cable from the KD-Pro8x8D to a network router or connect a straight-
through cable directly from a PC
»
Default IP address is 192.168.1.239, with default port 23
›
Firmware Mode Switch
»
Should remain in Operation setting unless instructed by Key Digital technical support
»
If changing position of switch, do so only with matrix unit not powered
»
Not every firmware update requires the switch to be set to the F/W Load position
»
If set to F/W Load, all front LEDs will be illuminated, indicating that unit is in bootloader
mode and awaiting a firmware load.
›
Micro USB (front panel)
»
Typically used for unit configuration, control, and firmware updates
»
It is most commonly used with KD-Wizard
®
software downloaded at