5
›
For RS-232 control use pins 4, 5, and 6 of the Main Control port
Connection Protocol:
»
Baud Rate = 57,600 bits per second
»
Data Bits = 8
»
Stop Bits = 1
»
Parity = Non
»
Flow Control = None
»
Carriage Return: Required at end of string
›
For TCP/IP control, the
default static IP address is 192.168.1.239, with port 23
Default static IP address:
192.168.1.239, port 23
›
For the past 10 years, most Key Digital switches have supported a standard HDMI switching
command. KD-Pro2x1X/KD-Pro4x1X is also controllable by this command, so if you have previously
integrated Key Digital matrixes by third-party control systems you may have success using the same
driver/module.
»
SPOxxSIyy
: Matrix Switching – Video + Audio together
»
xx = output number (01)
»
yy = input number (01-02 / 01-04)
Test for proper operation of the unit and cables in your system before permanently
securing the unit for final installation. Ensure that you leave enough ventilation
space to provide sufficient airflow and cooling.
Rack Mounting:
KD-Pro2x1X/KD-Pro4x1X includes a half-rack blank and a standard short rack ear for mounting in a
standard-with rack. If you wish to mount two units side by side you may do so with optional KD-BKTHF.