background image

Page 4

Page 5

Serial IR & IR Emitter Control

 

½

The “Serial IR” port requires the use of a Male 3.5mm Mono cable (not included) with the IR 
command signal being carried on the “Tip” of the input inserted into the KD-HDSW unit.  The 
location of the IR signal may vary by control system used.  Please verify the location of the IR 
signal with your control system.

 

½

When using the IR Emitter / IR Extender (sold separately), the 
IR Emitter must be mounted over the IR Sensor on the KD-
HDSW unit.  It is recommended that the rear IR sensor of the 
KD-HDSW unit be utilized for these applications. One end of 
the cable is connected to the IR Receiver / Master Controller 
/ IR Extender / IR Connecting Block, while the other end is 
mounted over the IR Sensor of the KD-HDSW unit.

RS-232 Commands and Protocol

 

½

KD-HDSW units are compatible with all Control Systems, such as AMX

®

, Control4

®

, Crestron

®

RTI

®

, Universal

®

 

½

Connect your Control System’s Master Controller to the KD-HDSW unit using the RS-232 port.  
Follow all instructions provided with your control system.

 

½

RS-232 Protocol:

 

»

Baud Rate = 9600 bits per second

 

»

Data Bits = 8

 

»

Parity = None

 

»

Stop Bits = 1

 

»

Flow Control = None

RS-232 Command List:

RS-232 Command

Description

Comments

pwr_1

Power On

pwr_0

Power Off

sel_x

x = 1-4, 5, 6

1-4 = Input #, 5 = Up, 6 = Down

asl

Auto Select Enable/
Disable

hep

Help

Full RS-232 command listing

sta

Status

“s1y” y = active input

sir_x_x_y

Addressing per 
Command

x x = desired two-digit address for 
command (01 – 99) 
y = Input Select, Up, Down (1-4, 5, 6)

gir

Address Setting Status

dir_y

Delete Address Setting 
per Command

y = Input Select, Up, Down (1-4, 5, 6)

 

½

All RS-232 commands must be in lower case letters, require spaces where indicated above with 
( _ ), and require a carriage return to be sent.

Multiple KD-HDSW Unit Configurations

Up to 99 individually addressable units can be installed.  KD-HDSW switchers allow you to assign 
a two-digit address to each unit or each of the selectable inputs.  This capability can be configured 
via IR or the RS-232 port.

 

½

Addressing Buttons / Units via IR

 

»

With power enabled on the unit, press the “Power On” button.  The “Input Select” LED 
lights will begin to blink, indicating that the KD-HDSW unit is ready to receive the address 
information.

 

»

Press the first digit (0 – 9) of the two-digit address.  Once this first digit has been received 
“Input Select 1” LED will blink.  

 

»

Press the second digit (0 – 9) of the two-digit address.  Once this second digit has been 
received “Input Select 1” and “Input Select 2” LED’s will blink.

 

»

Press the Input Select button (Input 1 – Input 4, Up or Down) that you wish to assign the 
two-digit address to.  Once this is completed, all “Input Select” lights will become solid 
indicating that the Input Select button has now been re-addressed.  

 

»

Repeat Steps 2 through 4 if you wish to assign an address to additional “Input Select” 
buttons or to your entire KD-HDSW unit.  

 

»

Press “Power On” button to exit addressing mode when completed.  

 

½

Addressing Buttons / Units via RS-232

 

»

See “RS-232 Commands and Protocol” section for RS-232 Addressing Commands

 

»

To address an Input, use “sir_x_x_y” command.  To address an entire unit, repeat command 
for each Input, Up, and Down

 

»

For address settings, use “gir” RS-232 command to receive a list of address settings

 

»

To delete address settings, issue “dir_y” RS-232 command

Ground

Signal

Summary of Contents for KD-HDSW2X1

Page 1: ...ristine picture and sound quality Phantom Series HDMI switchers are a transparent solution for all digital video audio switching applications and support all HD and SD video standards including 1080p...

Page 2: ...Step 5 Connect the desired IR or RS 232 control inputs to your KD HDSW unit Step 6 Be sure the Operation Mode Switch is set to the Normal position Step 7 Connect power to the KD HDSW unit Step 8 Power...

Page 3: ...st for proper operation of the unit and the cables in your system It is recommended that you leave enough ventilation space to provide sufficient airflow and cooling especially if you are going to lea...

Page 4: ...per Command y Input Select Up Down 1 4 5 6 All RS 232 commands must be in lower case letters require spaces where indicated above with _ and require a carriage return to be sent Multiple KD HDSW Unit...

Page 5: ...es as provided and instructed by Key Digital Periodically check out web site at www keydigital com for the latest firmware updates for your unit Firmware Upgrade Procedure 1 Make sure you have the req...

Page 6: ...ck anchors Safety Instructions Please be sure to follow these instructions for safe operation of your unit 1 Read and follow all instructions 2 Heed all warnings 3 Do not use this device near water 4...

Page 7: ...e high quality video imaging is important Key Digital is at the forefront of the video industry for Home Theater Retailers Custom Installers System Integrators Broadcasters Manufacturers and Consumers...

Reviews: