23
EN
PARAMETERS
DESCRIPTION
DEFAULT
CONFIGURATION MIN
MAX
UNIT
1
EL
.
F
.
Electric brake
0 = off
1 = on
0 *
0
100
x 0.01s
(step of 5)
2
SP
.
h
.
Use of PHOTO1 when starting from closed
0 = PHOTO1 is checked
1 = The gate starts even with PHOTO1 excited
1
0
1
3
Ph
.
2
.
Use of PHOTO2
0 = Enabled during both opening and closing AP/CH
1 =Only enabled during opening AP
0
0
1
4
tP
.
h
.
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
0
0
3
5
Ed
.
m
.
Sensitive edge type
0 = contact (NC)
1 = resistive (8k2)
0
0
1
6
iE
.
D
.
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
0
0
1
7
tE
.
D
.
Edge test
0 = off
1 = on
0
0
1
8
LP
.
o
.
Pedestrian opening
30
0
100
% (step of 1)
9
TP
.
C
.
Time for automatic closure from pedestrian opening
(0=off)
20
0
900
s
10
FP
.
r
.
Flashing light output setup
0 = Steady
1 = Flashing
1
0
1
11
tP
.
r
.
Pre-flashing time (0 = off)
0
0
10
s
12
FC
.
Y
.
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not duration of TCY
2 = On if courtesy light timer (TCY) time not out
3 = Gate open light on/off
4 = Gate open light proportional flashing
0
0
4
13
tC
.
Y
.
Courtesy light on time
0
0
900
s
(step of 10s)
14
de
.
a
.
Hold-to-run
0 = off
1 = on
0
0
1
15
se
.
r
.
Service interval cycle threshold. Once the set
threshold is reached, the light flashes
at high speed in all subsequent cycles (only if FPR is
on).
(0 = off)
0
0
100
x 1000
cycles
16
se
.
f
.
Enabling of continuous flashing indicating
service required (only active with gate closed).
0 = off
1 = on
0
0
1
17
de
.
f
.
Restoring the default values
6 - FURTHER DETAILS - ADVANCED MENU
The
ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu
To access the ADVANCED menu, press the MENU key and hold it
To set the default values: 1) access the advanced programming
function; 2) select the “dEf” parameter”; 3) activate the modification
mode (“0” on display”); 4) accept the modification (press “MENU”
down for 5 seconds
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU
and hold it down). A countdown should now appear: d80,d79...,d01
down to “
don
“. Release the key when finished.
* for
900CT102I default value = 15
Summary of Contents for CT102
Page 13: ...13 IT NOTE ...
Page 25: ...25 EN NOTES ...
Page 37: ...37 FR REMARQUES ...
Page 49: ...49 ES NOTAS ...
Page 61: ...61 DE ANMERKUNGEN ...
Page 73: ...73 PT OBSERVAÇÕES ...
Page 85: ...85 PL UWAGI ...
Page 86: ...86 UWAGI ...