21
EN
Before installing the product, perform the following checks and
inspections:
check that the gate, the door or the barrier is suitable for automation;
the weight and size of the gate or door and the balance of the
barrier boom must be within the operating limits specified for the
automation system in which the product is installed;
heck that the gate or door has firm, effective mechanical safety
stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the
product to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide
temperature variations or high temperatures), friction may
increase, causing a corresponding rise in the force needed to
operate the system;
the starting torque may therefore exceed that required in normal
conditions;
check that when operated by hand the gate, the door or the barrier
moves smoothly without any areas of greater friction or derailment
risk;
check that the gate, door or the barrier is well balanced and will
therefore remain stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and
differential safety breaker device;
he system power supply line must include a circuit breaker
device with a contact gap allowing complete disconnection in the
conditions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
3 - PRELIMINARY CHECKS
TECHNICAL SPECIFICATIONS
Power supply (L-N)
230 Vac (+10% - 15%) 50-60 Hz
Max motor load
150 W
Output for Vac accessories power
Device test power Vdc
24 Vac without regulation 200 mA
24 Vdc without regulation 250 mA
Courtesy light output
24 Vdc 25 W
Flashing light output
24 Vdc 25 W
Pause time
Adjustable 0-900 sec.
Operating temperature
-20 °C + 55 °C
230 Vac power supply line fuses
1.6 A slow-acting
Max. number of transmitters storage FIX CODE
150 transmitters
Max. number of transmitters storage ROLLING CODE
150 transmitters
The cables required for connection of the various devices in a
standard system are listed in the cables list table.
The cables used must be suitable for the type of installation; for
* If the power supply cable is more than 20 m long, it must be of larger gauge (3x2.5mm
2
) and a safety grounding system must be installed
near the automation unit
** Two cables of 2 x 0.5 mm
2
can be used as an alternative
example, an H03VV-F type cable is recommended for indoor
applications, while H07RN-F is suitable for outdoor applications.
2.4 - List of cables required
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
Connection
cable
maximum allowable limit
Control unit power supply line
1 x cable 3 x 1,5 mm
2
20 m *
Flashing light, courtesy light
Antenna
3 x 0,5 mm
2
**
1 x cable type RG58
20 m
20 m (advised < 5 m)
Electric lock
1 x cable 2 x 1 mm
2
10 m
Transmitter photocells
1 x cable 2 x 0,5 mm
2
20 m
Receiver photocells
1 x cable 4 x 0,5 mm
2
20 m
Sensitive edge
1 x cable 2 x 0,5 mm
2
20 m
Key-switch
1 x cable 4 x 0,5 mm
2
**
20 m