Kewtech KT1795 Instruction Manual Download Page 3

References marked on instrument or in instruction 
manual:

   Warning of a potential danger, follow with instruction 

manual.

  Reference! Please use utmost attention.
   Caution! Dangerous voltage. Danger of electrical shock.

  Equipment for working under live voltage

   Continuous double or reinforced insulation category II 

IEC 536 / DIN EN 61140.

   Conformity symbol, the instrument complies with the 

valid directives. It complies with the EMV  Directive 
(2014/30/EU), Standard EN 61326-1 are fulfilled. It also 
complies with the Low Voltage Directive (2014/35/EU), 
Standard EN61243-3:2014 is fulfilled.

 

UK Conformity compliance mark

   Tester complies with the standard  

(2012/19/EU) WEEE.

   The instruction manual contains information 

and references, necessary for safe operation and 
maintenance of the tester. 

 

 Prior to using the tester (commissioning/ assembly)  
the user is requested to thoroughly read the 
instruction manual and comply with it in all sections.

   Failure to read the tester manual or to comply with the 

warnings and references contained herein may result in 
serious bodily injury or tester damage.

 

 The respective accident prevention regulations 
established by the professional associations are to be 
strictly enforced at all times.

   Voltage tester is not a measurement device, it is only 

allowed to use for testing purposes.

1.0  INTRODUCTION / PRODUCT PACKAGE

The voltage tester KT1795 is a universally applicable tester 
for voltage testing, continuity testing, rotary field testing and 
trip testing of RCD. 
The voltage tester KT1795 is characterized by the following 
features:
•    Designed to meet international safety standards.  

 EN61243-3:2014

•    Measurement Category (CAT.) IV 600V, III 1000V
•    AC and DC voltage test up to 1000Vac and 1500Vdc  

  with LCD

•    Polarity indication 
•    Single-pole phase test 
•   Phase rotation test
•    Trip Test of RCD
•    Continuity test 
•    Resistance test 
•    Auto-power ON / OFF 
•    Torch light
•    IP64 (IEC60529)
•    Lower load impedance option to clear ghost or 

interference voltages

Summary of Contents for KT1795

Page 1: ...KT1795 Current Voltage Tester Instruction Manual...

Page 2: ...ts 7 1Voltage Test 7 2 Single pole phase test 7 3 Phase Rotation Test 7 4 Trip Test of RCD Lower ImpedanceVoltage test 7 5 Continuity test Rx Diode test 7 6 Resistance test 7 7 Torch Light 7 8 Data Ho...

Page 3: ...instruction manual and comply with it in all sections Failure to read the tester manual or to comply with the warnings and references contained herein may result in serious bodily injury or tester dam...

Page 4: ...voltage source such as the KEWPROVE3 opening unit Make sure that the cables tested for current are double insulated The tester must no longer be used if one or more functions fail or if no functional...

Page 5: ...only be performed on double insulated cables If the indication voltage present appears although the checked part is considered as disconnected it is recom mended to verify additional measures if the m...

Page 6: ...t It can be switched on with the torch light button 6 2 Auto power off Tester is automatically powered off after 30 sec when there is no signal contacted to the probes The torch light switches off aft...

Page 7: ...ment under test aren t good enough Verification of live circuit shouldn t be dependent on this Single pole phase test only but on the voltage test Hold the tester well in your hand Connect the L2 prob...

Page 8: ...active Continuity test automatically switches OFF after approx 30 seconds if no continuity is detected When tester is OFF If continuity is detected it will be automatically switched on again 7 6 Resis...

Page 9: ...the battery door and replace the batteries Insert new batteries according to the engraving on the battery door Re assemble battery door Confirm that the battery door case is properly locked prior to m...

Page 10: ...s not pressed Is 3 5mA at 1000V Peak current with push buttons pressed Is 300 mA Measurement Duty 30s ON 240s OFF Internal battery consumption approx 80mA Single pole phase test voltage range 100 1000...

Page 11: ...o a level below the ELV but it will be back to the original value when the voltage detector is removed When the indication voltage present does not appear it is highly recommended installing earthing...

Page 12: ...It covers all manufacturing defects for a two year period but Kewtech reserves the right to exclude abuse or accidental damage RE CALIBRATION SERVICE Regular re calibration is recommended for this ins...

Reviews: