KEW 2200

Instruction Manual

COM

V/�

HOLD

OFF

A

V

V

600V

1000A

CAT. II 600V

CAT. III 300V

CAT. III 

digital clamp meter

KEW 2200

Current Sensor

Trigger

Function Switch

V/ΩTerminal

COM Terminal

LED

Data Hold Key

Mode Key

Lanyard

kewtechcorp.com

Summary of Contents for KEW 2200

Page 1: ...nstruction Manual COM V HOLD OFF A V V 600V 1000A CAT II 600V CAT III 300V CAT III digital clamp meter KEW 2200 Current Sensor Trigger Function Switch V Terminal COM Terminal LED Data Hold Key Mode Ke...

Page 2: ...0 000 0 005 4 199V 1 8 rdg 7dgt 45 65Hz 2 3 rdg 8dgt 65 500Hz 40V 3 20 41 99V 400V 32 0 419 9V 600V 320 629V DC V Auto Range Range Accuracy 400mV 0 0 419 9mV 1 4V 0 320 4 199V 1 0 rdg 3dgt 40V 3 20 41...

Page 3: ...47V typ 40k 40M Range Input protective voltage AC DC 600V 10 sec Measuring method Dual integration Over range indication OL Measurement cycle 2 5 times per second Applicable Standards IEC EN 61010 1 6...

Page 4: ...AC 5320Vrms 5sec between current sensor and enclosure AC 3540Vrms 5sec between circuit and enclosure Insulation resistance 100M 1000V between enclosure and electrical circuit Operating temperature and...

Page 5: ...guaranteed when the measured object is placed at the centre zone A of the Current Sensor In zone B 4 of tolerance should be added to the specified accuracy In zone C measured values should be conside...

Page 6: ...C V DC V Measurement DANGER 600V Never make measurement on a circuit in which voltage over 600V exists Black test lead ACV Red test lead DCV Black Red digital clamp meter KEW 2200 digital clamp meter...

Page 7: ...t in over 600V exists 5 Resistance Continuity Measurement WARNING Never use the instrument on an energized circuit Beeps when less than 50 30 Test lead Test lead Resistance Continuity LCD Press digita...

Page 8: ...nual for safe operation of the instrument It is essential to read the instructions wherever the symbol appears in the manual DANGER is reserved for conditions and actions that are likely to cause seri...

Page 9: ...from the service drop to the service entrance and to the power meter and primary over current protection device distribution panel Current measurement section of this instrument is designed for CAT II...

Page 10: ...instrument Firmly attach the Caps to the test leads when performing measurements at CAT III or higher test environment When the KEW2200 and the test leads are combined and used together whichever is...

Page 11: ...mpletely exhausted the LCD goes blank without showing mark Do not try to replace the batteries if the surface of the instrument is wet Disconnect the test leads from the object under test and power of...

Page 12: ...e customers legal rights it covers all manufacturing defects for a two year period but Kewtech reserves the right to exclude abuse or accidental damage To register your free guarantee simply go to kew...