INSTALLATION GUIDE

770-000026-01 r08

Note: This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for help.

Shock Hazard. May result in serious injury or death.

Turn power OFF at circuit breaker or remove fuse. Damage to this 

product caused by wiring with power on voids the warranty.

Due to risk of electric shock, a licensed electrician should install this power 

supply unit in strict compliance with the National Electric Code and any state or 

local code which may apply. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that 

may cause undesired operation.

!

!

WARNING

Summary of Contents for X 2

Page 1: ...X2 I NS TALL ATION GU I DE Supported models X2 ND KetraNet Mesh Keypad 120 277V X2 INC KetraNet Mesh 600W Incandescent Dimmer 120V Available in multiple colors Refer to specifications sheet ...

Page 2: ...t the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shock Hazard May result in serious injury or death Turn power OFF a...

Page 3: ...8 Product Overview page 4 Included Components Specs page 5 Dimension Drawings page 6 Dimmer Load page 7 Wiring Diagrams page 8 Installation page 10 Replacing Button Chassis page 16 Operation page 17 Warranty Tech Support page 18 TABLE OF CONTENTS ...

Page 4: ...d a wireless KetraNet Mesh controller with onboard incandescent dimmer The latter is ideal for spaces where both Ketra and traditional lighting sources need to be controlled Fitting within a standard wall box and either Decora or Claro wall plates the X2 is perfect for retrofit installations as well as new construction X2 Mounting Screws Wall Plate Mounting Screws Backbox X2 With Button Chassis Wa...

Page 5: ...6 INCLUDED COMPONENTS SPECS Environmental Ambient Operating Temperature 0 to 40 C Storage Temperature 20 to 80 C Humidity 0 95 Non condensing Certification UL cUL FCC Class B RoHS Location UL Damp location IP20 Mechanical Weight 8 8oz 250kg Housing Material Flame Retardant Polymer Wireless Frequency 2405 2480 MHz Output Power 18 20 dBm Electrical Input Wiring 16 AWG Flying Leads Voltage X2 ND 120 ...

Page 6: ...THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF KETRA INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF KETRA INC IS PROHIBITED PROPRIETARY 2 6 66 23mm 1 3 32 98mm 3 3 83 60mm 4 1 105 00mm 1 7 43 97mm MULTI GANG TRIM 2 4 60 15mm 3 7 60mm 1 4 35 30mm 2 6 10mm 3815 S DRAWN DATE SCALE CHECKED FOR C DRAWING REVISION DRAWING X2 K DOC N 07 THE INFORMATION CON...

Page 7: ...1 r08 DIMMER LOAD X2 INC Load Type and Capacity Chart Load Type Single Gang Multigang Incandescent 600W 500W Dimmer capacity rated at 25 C ambient temperature derate incandescent and halogen loads an additional 100W at 40 C temperature ambient ...

Page 8: ...WIRING DIAGRAMS X2 and load on same circuit should be wired in parallel not series Retrofit Installation 120V 50 60 HZ X2 KEYPAD ND X2 KEYPAD INC 120 277V 50 60 HZ ND INC SWITCH LOAD SWITCH 3 Way Switch SWITCH LOAD SWITCH X2 Keypad Ketra Retrofit ND ...

Page 9: ...PAGE 9 X2 INSTALLATION GUIDE 770 000026 01 r08 WIRING DIAGRAMS LOAD SPLIT SWITCHES 3 Way Switch LOAD SPLIT SWITCHES X2 Keypad Ketra Retrofit ND INC ...

Page 10: ...t See Figs 1 and 2 INSTALLATION 3 Run power to wall box utilizing stranded or solid core 12 18 AWG wire See Fig 3 4 Prepare the wire for connection to lead wire A Strip 8 5 mm of wire for insertion into the wire nut B Twist the stranded wire to prevent fraying tinning optional 5 Using the provided wire nuts attach each X2 lead wire to the corresponding conductor Black Line White Neutral Green Grou...

Page 11: ... the wall plate mount remove the mount and adjust the position of the X2 Secure the wall plate mount with the fasteners when satisfied 10 Place one serial number sticker on the back of the wall plate The other can go on building plans or control drawings See Fig 7 11 Attach Wall Plate to Wall Plate mount It will snap into place See Fig 8 12 Energize circuit Note Indicator lights will power on if u...

Page 12: ...ed by the X2 should have an uninterrupted source of power They should NOT be wired to a light switch or other intermediary device that could cut their power If you are replacing lamps that are already wired to a light switch it is recommend that the light switch be physically replaced by the X2 See Fig 9 Retrofit Instructions 1 Turn off power feed to the switch to be replaced 2 Remove existing swi...

Page 13: ...rrupted es being by the X2 he AC input INSTALLATION ELV DIMMER X2 __ ELV JB 1 __ ____ New Construction 1 Install wall box single gang wall box with at least 14 in3 cubic inch volume only 2 Run power to wall box utilizing stranded or solid core 12 18 AWG wire See Fig 1 2 1 3 Prepare the wire for connection to lead wire a Strip 8 5 mm of wire for insertion into the wire nut b Twist the stranded wire...

Page 14: ...ODES TO BE INSTALLED WITHIN 50 0 RANGE OF THE NEAREST NODE SHEET 3815 S CAPITAL OF TEXAS HWY SUITE 100 AUSTIN TX 78704 P 512 347 1100 OF SHEET NAME SCALE CHECKED BY DRAWN BY DATE REVISION DRAWING DRAWING TYPE FOR REFERENCE ONLY NOT FOR CONSTRUCTION 1 1 WD 00 05 10 2016 CEH GEB NTS KETRA X2 KEYPAD X2 INSTALLATION GUIDE PAGE 15 X2 INSTALLATION GUIDE 770 000026 01 INSTALLATION ELV DIMMER 7 6 7 Mount ...

Page 15: ...is wireless However non Ketra fixtures will need to be on the same circuit and wired in line if they are to be controlled by an X2 with onboard incandescent dimmer For a dimmer retrofit installation using incandescent loads the incoming and outgoing line connections should NOT be tied together Instead the incoming line should be tied to the X2 s black line wire while the outgoing line is tied to t...

Page 16: ... detached the light guide from the board reapply the light guide The light guide is a thin black rubber strip with chimneys on top See Fig 3 To reapply fit the two pegs on the underside of the light guide into the two square holes on the board Note The light guide s orientation matters Its surface should have a groove at the very bottom just above the last chimney 6 Apply replacement button chassi...

Page 17: ...ress to activate or deactivate stored scenes or shows Intensity Buttons Increase or decrease light intensity Double tap up or down to go to the max min intensity of the selected scene Airgap Switch Pull out to disconnect power to device Status LEDs Highlight activated button ...

Page 18: ... 18 X2 INSTALLATION GUIDE 770 000026 01 r08 WARRANTY TECH SUPPORT Limited warranty terms can be found at ketra com warranty For questions and technical support please contact 512 872 4357 support ketra com ...

Page 19: ...6321 E Stassney Ln Suite 400 Austin TX 78744 ketra com 512 347 1100 ...

Reviews: