Down Up
UU
130°
180°
UU
Down Up
safety sensor
!
!
889012121 U76 Page 25 of 29
left right
Standard drive technology
please use infrared remote control
Press and hold the “Up” key to extend the SME. In order to
retract the SME, press and hold the “Down” key. The fitting
can be moved from the bottom position (home position) to the
topmost lifting position.
Between the stop and an immediately following start
movement (Turn Lift, Lift Lift) the fitting pauses for a
mandatory 2-3 seconds. This is the time required by the
control unit to avoid an accidental activation of the safety
sensor.
Press and hold either one of the keys “Turn TV left” or “Turn
TV right”. The TV set will now move in the selected direction
until you release the key. The fitting may turn max. 130° to the
left and 180° to the right.
When installed in furniture the pivoting movement can be
carried out only in the topmost factory-set position. In the case
of a free-standing installation the pivoting movement can be
carried out only when the fitting has been raised at least 25
mm. In an emergency the fitting may be manually turned in
the desired direction if the remote control is defective. Should
the remote control be defective the turned screen can be
retracted into the furniture by using the handset and pressing
the “Down” arrow key. The fitting will first move back into
home position and then slide down into its compartment.
If you are unable to drive the f itting with the remote
control, press the “Down” ke y on the handset. The
fitting will now move back into home position and
then slide down into its com partment.
As soon as the screen has been dr
iven
downwards, the fitting will c
enter itself 25mm
before reaching its home pos
ition.
Pivoting of fitting