15/15
H
D
E
K
E
1
12.
000
1.0
10.
428.
00
00.
00
40
37240
000
7.3 Battery change
» For step by step instructions, see picture section on page
, point 7.3.
8. Disposal
» Please comply with the respective national and local regulations when
disposing of or recycling the fitting or its components!
9. Troubleshooting
10. Technical data
NOTE
» Dispose of old battery in an environmentally friendly manner.
Problem
Cause
Remedy
Not working
Mains voltage not present
Check whether power plug
has been inserted
Plug connections have no
contact
Check all plug connections for
proper contact
After 2 minutes of
continuous operation -
stop for 8 minutes
Wait for 8 minutes
Unable to perform
reference run
Push-button sender / drive
unit coordination not car-
ried out
Perform push-button sender
coordination, see chapter
Battery in push-button
sender empty, not present
or wrongly inserted
Insert new battery or check for
correct installation position,
see chapter
Reference run starts
but is not completed
Force setting of fitting does
not match flap weight
Perform force setting as per
point 12 of the Free flap fitting
installation instructions
Reference run re-
starts
Power failure
Perform reference run, see
chapter
NOTE
» Contact your specialist dealer if the fitting is still defective after performing the
described remedial measures or other problems arise.
Voltage / frequency / current strength
100 - 240 V AC / 50 - 60 Hz / 1.3 A
Wattage
60 Watt
Ambient temperature range
0 - 40 °C
Overvoltage category
Degree of protection 3
Protection type / degree of protection
IP2X / degree of protection 2
Radio frequency
2.4 GHz
Battery
CR 2032 Lithium button cell, 3 V
Standby power
≤
1 Watt
BA_MA_Free-Kesseböhmer.book Seite 15 Freitag, 12. Juni 2015 9:50 09