Problem
Possible Issue
Possible Solution (brief)
Confirmed
Notes
Unit rides
smoothly for
partial
open/close and
poorly for partial
open/close
Top of support frame not square
Check to see that the frame has been
extended equally on front and back
Top of support frame extended too far
and rubbing on guide
Lower frame to reveal approximately
1/4" gap from frame to guide
Frame is twisted or bent
Replace with new frame
Door isn't
aligned/flush to
face of cabinet
Needs adjustment
Follow adjustment procedures to adjust
door—remember to loosen center fixing
screw, adjust, tighten fixing screw
Runner/guide in wrong position
Verify proper depth of runner/guide,
reposition if needed
Door has a
springboard
effect during
opening
Frame is not properly engaged and/or
tightened
Follow the installation instructions to
ensure the frame is fully engaged into
slot and fully tightened
Horizontal tilt of frame/runner is level
or pitched forward
For best operation, adjust tilt so that the
frame is tilted up in the front slightly