5.37.10 Scheduled arm and disarm time setting
Syntax :1234+57+Group NO 01-04 + AAAA Scheduled time of arm+BBBB Scheduled time of
week #
Example: set up the second group scheduled time to arm at 12
:
00 am and disarm at 18:00 (means
06
:
00 pm), this is valid for Monday, Tuesday, Wednesday, Thursday and Friday of each week. send
message to the alarm panel:123457021200180012345#
5.37.11 Set the type of defense zone
Syntax:1234 +
【
60
】
+
【
00-99 zone number
】
+
【
1-8 Type
】
+
【
0/1
】
+
【
#
】
To set
99 zone type, 00-99 represents 0-99 zone number, 1-8 represents one of the 8 zone type: 1.NORMAL
2.STAY ARM 3.INTELLIGENT 4.EMERGENCY 5.CLOSED 6.CHIME 7.WELCOME
8.HELP SENIOR
The last 0/1 represents 0 siren of panel produce no sound upon alarming while 1 is sounded.send
message to the alarm panel:1234601880#
。
Example: Set zone number 18
th
as help senior zone type, and siren not sound upon alarming
5.37.12 Set mode of wired alarm zone
Syntax :1234+61+zone NO +51-52+0/1+# here 0 means NO and 1 means NC
NO means short-circuit to alarm
NC means open-circuit to alarm
Example:set the 51th zone as NO alarm ,send message to the alarm panel:123461511#
。
5.37.13 Zone setting
Syntax :[1234]+[64]+[zone NO 01-99] +[CID feature codes
AAA]+[#]
,
AAA means CID feature codes
100 is medical aid , 110 is fire alarm , 121 is robbery alarm , 122 is mute robbery alarm , 130 is
burglary alarm , 131 is peripheral burglary alarm , 151 is gas alarm
Example : set 38
th
zone is gas alarm ,send message to the alarm panel:12346438151#
。
5.37.14 Volume control of the voice prompt
Syntax :[1234]+[79]+[volume level 1-7] +[#]
Example: set the voice volume to be level 3 . send message to the alarm panel
:
1234793#
。
5.37.15 Hand shake Tone setting
Syntax :[1234]+[83]+[precision level 0-9] +[#] Example : set it to be 4 ,send the message to the alarm
panel:1234834#
。
5.37.16 Power saving mode setting
Syntax :[1234]+[84]+[1/0] +[#]
,
Example: set LCD keeps on ,send the message to the alarm panel:1234840#
。
5.37.17 Volume adjustment of
Internal
siren
Syntax : [1234]+[87]+[volume level 0-7] +[#]
,
Example :set it as 3,send the message to the alarm panel:1234873#
。
Note :set it as 0 means internal siren
would be not sound when alarming