KERUI DP-8218G User Manualr Download Page 15

 

 

15 

5

14    Set system voice ON or OFF   

As picture 5-4.press

3.Voice Setting

,then press

Down

move the cursor behind

System voice

.press

Menu

switch switch ON or OFF.OFF means the alarm system no voice in the operation, but with the 

press sound. 

 

5

15    Set the external alarm volume

 

As picture 5-4,press 

4.Siren Setting

,press 

OK

button move the cursor to 

External volume

】,

input the volume level 00-99,00 means mute, 99 the maximum sound.press 

OK

to save 

 

5

16    set the internal alarm volume 

As picture 5-4,press 

4.Siren Setting

,press 

Down

button move the cursor to 

Built-in volume

,then 

input the volume level 00-99,00 means mute, 99 the maximum sound 

 

5

17    Set length of Siren sound   

As picture 5-4,press 

4.Siren Setting

,press 

Down

button move the cursor to

Siren on time

,input 

0-20 minutes.0 is means no siren sound after alarm

 

 

5

18    Set number of ring tones for remote 

As  picture  5-4,press 

5.Phon&SMS  setting

,press 

OK

button  move  the  cursor  behind

Ring 

time

,then input the number of ring tones 1-20 ,0 indicates the host don't accept the cable remote set 

functions, 20 means the host is on the phone after received 20 times rings in continuous

 

 

5

19    Set the anti-tampering of telephone cord ON/OFF

   

As picture 5-4,press 

5.Phon&SMS setting

,press 

Down

button move the cursor to

Test line

,press 

Menu

switch ON or OFF 

 

5

20    Set the SMS Messaging reply ON/OFF

 

As picture 5-4,press 

5.Phon&SMS setting

,press 

Down

  move the cursor to

SMS reply

,press 

Menu

switch ON or OFF .On is means user sent the setting message to the alarm system host,the host 

will reply the setting is correctly. 

 

5

21    Set alarm Output ON/OFF

As picture 5-4,press 

5.5.Phon&SMS setting

,press 

Down

move the cursor to

Alarm Out

,press 

Menu

switch ON or OFF,On is means when the system is alarm, relay will short circuit output at the 

same time(COM and CO short circuit output) 

 

 

 

 

 

 

 

 

 

Summary of Contents for DP-8218G

Page 1: ...1 Touch Keypad TFT Color Display GSM PSTN Burglar Alarm System 8218G User Guider DP...

Page 2: ...ber 11 5 6 7 Set phone number to receive SMS message 11 5 6 8 Delete SMS phone number 12 5 6 9 Voice call 12 5 7 Pre record Voice Message 12 5 8 Add Accessories 12 5 8 1 Add Remote Control 12 5 8 2 De...

Page 3: ...larm history list record 17 5 36 Query Arm and Disarm history record 17 5 37 SMS commands 17 5 37 1 Set phone alarm number 18 5 37 2 Set center number 18 5 37 3 Set helpline number 18 5 37 4 Set SMS a...

Page 4: ...y the system date and time 20 5 37 35 Query the scheduled time of arm and disarm 20 5 37 36 Query the defense zone type 21 5 37 37 Query the alarm mode of the wired zone 21 5 37 37 Query the alarm mod...

Page 5: ...of time to alarm Long distance Control Call host number by telephone or phone can control the control panel when host number picking up System Password System default password 1234 System Volume Volum...

Page 6: ...OR Defense Zone This type of zone is for elderly safety no matter in what status the panel will alarm once sensor with this zone type is triggered System automatically dial 3groups help senior number...

Page 7: ...king setting up for relay and siren Wireless intelligent study coding compatible with PT2262 normal encoding and 1527 encoding Maximum support 150 remote control and 150 sensors Integrated clock chip...

Page 8: ...8 The touch key figure of the host...

Page 9: ...number for three times until connected When the user picks up the phone a piece of pre recorded voice message will be played back immediately and let the receiver noted about the event Upon receiving...

Page 10: ...ome events burglar fire gas leak etc happened and detected alarm system alarm right away In ARM status the host will display ARM To activate by remote control press ARM key once To activate by keyboar...

Page 11: ...re 5 1 5 6 1 Set up voice alarm phone number As picture 5 1 Press menu to enter main menu Press Up Down move the cursor to 1 Alarm numbers press OK or number 1 to enter Alarm number settings choose gr...

Page 12: ...hone line extension you should dial a number such as 9 to pick up a dialing tone press Arming to add a then input the alarm number 5 6 6 Delete for help alarm phone number As picture 5 1 enter Help nu...

Page 13: ...d 1st remote control please input 01 add 22th remote control please input 22 then press OK to save the settings Then press any key of the remote control to send a signal to the alarm panel voice promp...

Page 14: ...as to delete all detectors Then press OK to delete certain zones detector or all detectors 5 9 Set delay for system arm Picture 5 4 As picture 5 4 choose 1 Delay settings input the delay time from 0 t...

Page 15: ...alarm 5 18 Set number of ring tones for remote As picture 5 4 press 5 Phon SMS setting press OK button move the cursor behind Ring time then input the number of ring tones 1 20 0 indicates the host do...

Page 16: ...one As picture 5 5 press 8 CID setting then OK Input the 0 9 to behind Hand shake Tone Press OK to save 5 26 Set the mode of uploading arm disarm message As picture 5 5 press 8 CID setting then OK mov...

Page 17: ...ones types call number group when arming wired zones NO alarm or NC alarm Setting method is as follows Picture 5 6 5 33 1 Setting CID event codes As picture 5 6 input defense zone 1 99 behind Enter Nu...

Page 18: ...Number press OK then press down move the cursor behind Wired model press Menu switch the NO alarm NC alarm press OK to save 5 34 Set the time of alarm system Picture 5 7 As Picture 5 7 input the date...

Page 19: ...mber Example to set 13812345678 as the first group SMS alarm number send message to the alarm panel 12344113812345678 5 37 5 Set the password Syntax 1234 50 4digits password Example to set 9876 as the...

Page 20: ...here 0 means NO and 1 means NC NO means short circuit to alarm NC means open circuit to alarm Example set the 51th zone as NO alarm send message to the alarm panel 123461511 5 37 13 Zone setting Synta...

Page 21: ...21 Set the number of ring tones before picking up Syntax 1234 18 0 20 Example set it to 6 send the message to the alarm panel 12341806 5 37 22 Restore the factory setting Syntax 1234 9898 5 37 23 Arm...

Page 22: ...losed 5 key turn on announcement 6 key turn off announcement 7 key siren ringing 8 key stop siren sound key hang up system will not dial the next number on list Remark Monitoring time and announcement...

Page 23: ...nsor can be attached to the door and frame firmly with double faced adhesive 1 Each kit door sensor include sensor A as in diagram and magnet B as in diagram B must be the right hand side A and B one...

Page 24: ...r hole of base and then adjust the best angle of detecting This method is suitable for engineering installation Attention 1 Within coverage of detection there should be no any objects for obstruction...

Page 25: ...es caused by corrosion 4 contact the local dealer to change the matched remote controller 5 infrared detector no work low power change to the same type battery 6 Infrared Beams not work 1 not power on...

Reviews: