3  Basic Information (General) 

 

 

Intended use

 

 

This device allows medical staff to test a patient‟s fitness sta-
tus and to carry out controlled training during the rehabilitation 
process. 

The appliance should be checked for correct condition prior to 
each utilisation by a person familiar with proper operation of 
the balance. 

 

 

 

Non-intended 

use

 

 

Changes to the unit's design are not permitted. This may lead 
to incorrect measuring results, safety-related faults and de-
struction of the unit. 

The unit may only be operated in accordance with the de-
scribed default settings. Other areas of use must be released 
by KERN in writing. 

 

 

Warranty 

Warranty claims shall be voided in case  

 

  Our conditions in the operation manual are ignored 

  The appliance is used outside the described uses 

  The appliance is modified or opened 

  Mechanical damage and damage caused by media, liquids 

  Natural wear and tear 

  Non-intended use or electric installation 

  The measuring system is overloaded 

  Dropping the balance 

 

Test device 

control 

As a precautionary measure during quality control, the metro-
logical features of the device  have to be tested on a regular 
basis. The responsible user must define a suitable interval as 
well as type and scope of this test. For further information 
please go to KERN-Homepage (HYPERLINK http://www.kern-
sohn.com 
under www.kern-sohn.com).  

 

 

 

Summary of Contents for PROMAT MAP 130K1

Page 1: ...Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instructions Hand Grip Dynamometer KERN MAP Version 1 2 08 2012 G...

Page 2: ...ter Table of Contents 1 Technical Data 3 2 Appliance overview 8 3 Basic Information General 9 4 Basic Safety Precautions 10 5 Transportation Storage 10 6 Removing packaging and initial start up 11 7 O...

Page 3: ...ability d 0 1 kg 0 2 lb Units kg lb Auto Off After 1 min without change of load Electric Supply 1 x CR2450 Service life 53 h Operating temperature 5 C 35 C Storage temperature 20 C 60 C Humidity of ai...

Page 4: ...bility d 0 1 kg 0 2 lb Units kg lb Auto Off After 1 min without change of load Electric Supply 1 x CR2450 Service life 53 h Operating temperature 5 C 35 C Storage temperature 20 C 60 C Humidity of air...

Page 5: ...d 0 1 kg 0 2 lb Units kg lb Auto Off After 1 min without change of load Electric Supply 1 x CR2450 Service life 53 h Operating temperature 5 C 35 C Storage temperature 20 C 60 C Humidity of air max 8...

Page 6: ...6 MAP BA e 1212 1 1 Dimensions MAP 80K1S...

Page 7: ...MAP BA e 1212 7 MAP 80K1 MAP 130K1...

Page 8: ...8 MAP BA e 1212 2 Appliance overview 1 Battery compartment see chapter 7 2 Display see chapter 8 3 Keyboard see chapter 8 4 Spring set see chapter 7 Transport case...

Page 9: ...ettings Other areas of use must be released by KERN in writing Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the des...

Page 10: ...nal document in German Staff training The medical staff must apply and follow the operating instruc tions for proper use and care of the product 5 Transportation Storage Testing upon acceptance When r...

Page 11: ...me dampness for longer periods of time Non permitted condensation condensa tion of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment If present...

Page 12: ...1212 How to replace a spring set 1 Press device until the two screws 1 become visible 2 Remove screws 3 Remove grip first followed by springs 4 Insert desired spring set 5 Reassemble device in revers...

Page 13: ...MAP BA e 1212 13 Install two additional washers only in the 130 kg spring set s fig...

Page 14: ...save battery power the device auto disconnects automati cally after 60 seconds have passed without a change of display If the batteries are run down soon LO appears in the display Replace battery If...

Page 15: ...MAP BA e 1212 15 Commissioning Correct left hand right hand...

Page 16: ...16 MAP BA e 1212 Correct left hand right hand...

Page 17: ...MAP BA e 1212 17 wrong...

Page 18: ...bility display 2 Battery status 3 Operation modus 4 Percentage display 5 Weighing unit lb 6 Weighing unit kg Keyboard overview Button Function Zero Switch on off zeroing Mode Select operating mode Set...

Page 19: ...ero key Zero display appears If the device does not exactly show zero unload the device and press the zero key To switch off keep zero key pressed for approx 3 seconds During power up the device will...

Page 20: ...ice to the following operating modes Operating mode Display Function Real time mode Shows current strength Counting mode Counts number of gripping actions exceeding a previously set strength limit Ave...

Page 21: ...l strength Relieve Press Release 2 Change unit kg lb In real mode it is possible to switch from kg to lb by pressing the set key and vice versa During power up the device will return to the mode or un...

Page 22: ...lay ap pears 2 How to define the strength limit The currently set strength limit is displayed To change press the mode key repeatedly until the de sired strength limit is displayed Ensure that the cap...

Page 23: ...e as often as possible Each gripping action is acknowledged by an audio sound The number of gripping actions carried out will be shown on screen 4 Start further counting Press the Zero button the zero...

Page 24: ...ssing the zero key Press mode key repeatedly until avg display appears 2 Determine average strength from two hand grips Carry out first gripping action Strength of first hand grip will be shown Carry...

Page 25: ...rived from the two hand grips will be calculated and displayed flashing 3 Start further measurements To return to measuring mode press the set key Press the Zero button the zero display disappears Car...

Page 26: ...xample Example A gripping action achieves a strength of 50 kg Now you are able to determine whether follow up measurements also reach 50 kg 100 or for example only 31 15 5 kg ad justable range 1 100 C...

Page 27: ...to confirm If a new gripping action shows a strength of less than for in stance 31 15 5 kg the previous max value will be re tained If a new gripping action shows a strength greater than for in stance...

Page 28: ...fluid from penetrating into device Finish by polishing with dry soft cloth Remove dirt immediately Service main tenance The appliance may only be opened by trained service techni cians who are author...

Page 29: ...ted For replacing of batteries see chapter 7 Underload set to zero by pressing zero key Overload release device Preload error put minor stress on device during power up EEPROM error switch off and res...

Reviews: