HSF 600W 042315
13
FIGURE 10. OUTPUT ALARM CIRCUIT OPTICALLY ISOLATED
FIGURE 11. ±PF POWER FAILURE OPTOCOUPLER TIMING DIAGRAM
3.8
LOCAL/REMOTE SENSING
HSF 600W Power Supplies allow remote error sensing which can compensate up to 0.4 Volts per
load wire. Local/Remote error sensing is configured by means of separate DIP switches mounted
on the RA 19-4C Rack Adapter (see RA 19-4C Rack Adapter Operator Manual). Either local or
remote sensing MUST be used, otherwise the units will not operate.
3.9
RETAINING LATCHES
HSF 600W series power supplies are provided with (2) retention latches located at each side of
the bottom edge of the front panel (see Figure 5). These latches work in conjunction with the RA
19-4C rack adapters to prevent unauthorized or inadvertent module extraction from an operating
power system. The latch is engaged by loosening the cap-head screw approximately 1/2 turn
CCW (use 5/32" hex key) and sliding the latch down to the bottom of the slot, then retightening the
cap-head screw CW until snug. DO NOT OVERTIGHTEN! To release, follow the same procedure,
except lift the latch to the top of the slot. Be sure to move the latch completely up or down to
ensure full engagement and disengagement of the latching mechanism. When the HSF power
supply is not installed in its plug-in rack adapter, it is recommended that the latch be secured in
the open (up) position to prevent damage.
NOTE: Retaining latches must
not
be used to secure the HSF power supply in the rack
adapter for shipping purposes.