3-28
BOP HIPWR 091719
3.3.9
STORING/RECALLING POWER SUPPLY OUTPUT SETTINGS
The power supply settings (mode, main channel reference type and setting, protection limit type
and setting and output status) can be stored in one of 99 memory locations for later recall. This
feature is accessible from the front panel by pressing
!
from the power-up screen to view the
Saved Settings screen (Figure 3-10). For a description of abbreviations used, refer to PAR.
3.3.9.1 To view previously saved settings refer to PAR 3.3.9.3. To save the power supply set-
tings or modify previously saved settings refer to PAR. 3.3.9.3. To recall saved settings and
apply them to the output refer to PAR. 3.3.9.5.
TABLE 3-8. EXAMPLES SHOWING HOW POWER-UP SETTINGS FUNCTION
Mode of
Operation
Main
Channel
Protection
Power-up condition (output set to ON)
(All referenced pins located on Analog I/O Port
Reference
Setting
Type
Levels
Voltage
Internal
5.0000
Internal
Voltage: 10
Current: 25
Unit powers up in voltage mode, +5V, ±current protection set to
25A. Pressing
MODE
changes mode to current, puts unit in
standby: output to 0A, ±voltage protection to power-up setting
of 10V, output off and STANDBY indicator on.
Current
Internal
-8.0000
Internal
Voltage: 10
Current: 25
Unit powers up in current mode, -8A, ±voltage protection set to
10V. Pressing
MODE
changes mode to voltage, puts unit in
standby: output to 0V, current protection to power-up setting of
25A, output off and STANDBY indicator on.
Voltage
External
or
ExtRefLevel
N/A
Internal
Voltage: 10
Current: 25
Unit powers up in voltage mode, output voltage determined by
Analog port, pin 11 (see PAR. 3.4.4.1 for External, PAR. 3.4.4.2
for ExtRefLevel), ±current protection set to 25A. Pressing
MODE
changes mode to current, puts unit in standby, ±voltage
protection to power-up setting of 10V. When output is on
(STANDBY indicator off), output current determined by pin 11.
Current
External
or
ExtRefLevel
N/A
Internal
Voltage: 10
Current: 25
Unit powers up in current mode, output current determined by
Analog port, pin 11 (see PAR. 3.4.4.1 for External, PAR. 3.4.4.2
for ExtRefLevel), ±voltage protection set to 10V. Pressing
MODE
changes mode to voltage and puts unit in standby, ±cur-
rent protection to power-up setting of 25A. When output is on
(STANDBY indicator off), output voltage determined by pin 11.
Voltage
Internal
3.0000
External
or Lesser
Limit
N/A
Unit powers up in voltage mode, 3V, ±current protection deter-
mined by pins 5 and 13 (see PAR. 3.4.5 for External, PAR.
3.4.5.1 for Lesser Limit). Pressing
MODE
changes mode to
current, puts unit in standby. When output is on, (STANDBY
indicator off), ±voltage protection determined by, pins 6 and 14.
Current
Internal
7.000
External
or Lesser
Limit
N/A
Unit powers up in Current mode, 7A, ±voltage protection deter-
mined by pins 6 and 14 (see PAR. 3.4.5 for External, PAR.
3.4.5.1 for Lesser Limit). Pressing
MODE
changes mode to
voltage, puts unit in standby. When output is on, (STANDBY
indicator off), output voltage is 0V, ±current protection deter-
mined by, pins 5 and 13.
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......