Resistive. 

This mode, as the name suggests, is

useful for resistive loads. Table 5 indicates how the
power supply responds to a command to go from
Output ON to OFF.

WARNING

Accessing the BOP after the output
is disabled in BATTERY mode is
hazardous because (1) high current
arcing is possible and (2) either the
external battery voltage, or the volt-
age (±Voltage Protection max) on
the BOP output terminals may be
dangerous. Therefore, for battery
and constant-voltage-type active
electronic loads it is recommended
that two properly rated external
switches be installed for safety:
one in series with the battery, and
one across the BOP output. After
the unit is set to OFF, first open the
switch in series with the battery,
then close the switch across the
BOP output to ensure safety before
handling BOP connections. When
connecting the battery, the switch
across the output should be
opened after the connections are
complete and then the switch in
series with the battery should be
closed. If the constant-voltage-type
active electronic load is adjusted to
zero before handling the power
supply-to-load connections, only
the switch across the BOP output
is required.

Battery

. This mode is necessary for the power sup-

ply to function properly and safely with either battery
or constant-voltage-type active electronic loads.
This mode prevents the battery from discharging
during the OFF state. When the output is disabled
(set to OFF), the BOP will go to current mode, cur-
rent will be set to zero, with voltage protect and cur-
rent limit set to maximum. In this way the battery will
not be discharged while the output is OFF. For con-
stant-voltage-type active electronic loads this mode
stops energy flow during the OFF state. Table 5 indi-
cates how the power supply responds to a command
to go from Output ON to OFF. 

CONFIGURE LOAD TYPE. 

To configure, press

%

 from the power-up screen, then highlight Load

Type and press 

!

 to modify. (If a Password is

required, see Operator’s Manual for instructions.)
Highlight Active, Resistive or Battery (see explana-
tions and associated WARNINGS above) and press

$

 to save. Then press 

$

 to save for power-up,

#

 to abort, or 

%

 to apply the changes (without

saving for power-up) and exit. After configuring, the
new setting will be effective when the power supply
goes from output on to output off.
To restore factory default (Active), press 

%

 from

the power-up screen, highlight Load Type, press

!

, then press 

@

 to restore default. Press 

$

 to

save for power-up or 

%

 to exit

ENABLING/DISABLING OUTPUT POWER. 

The BOP output can be disabled (OFF) or enabled
(ON) by toggling the 

STANDBY

 key in local mode.

The behavior of the unit when disabled depends on
the Load Type setting (See “Determining How the
Unit Responds when Output is OFF (Load Type)” on
page 12.  and Table 5 for details). 

IX — ADDITIONAL FEATURES.

 The user is urged to refer to the Operator’s Manual
for full explanations all BOP 1KW features, includ-
ing:

• Passwords - three independent levels of

access

• Changing the Default Power up Settings
• Digital Remote Operation - using SCPI com-

mands via RS 232 or GPIB ports

• Analog Remote Operation - via Analog I/O

port

• Details about Protect Limits and Software-

controlled limits

• Storing/Recalling Power Supply Output Set-

tings

• Waveform Generation - Sine, Triangle,

±Ramp, Square and Level segments. Local
operation allows up to 16 waveforms, maxi-
mum 10 segments per waveform. Remote
operation allows 1 waveform, maximum of
126 segments, or using LIST commands.

• Operator Testing
• Calibration - via either local keypad or remote

SCPI commands

• Parallel/Series Configurations -increase cur-

rent capability, voltage capability, or both.

Summary of Contents for BOP 10-100MG

Page 1: ...inted as a handy reference The BOP 1KW MG Operator s Manual also includes a full description of the digital interfaces and the SCPI command language FIRMWARE VERSION Refer to www kepcopower com suppor...

Page 2: ...cell arrays and powering many electrochemi cal reactions II UNPACKING This instrument has been thoroughly inspected and tested prior to packing and is ready for operation After careful unpacking insp...

Page 3: ...112113 228 1692 REV 3 3 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 4: ...to DTE equipment and one with female pins to connect to a PC personal com puter two RS 232 Loop Back test Connectors one 6 pin and one 8 pin to test RS 232 communication and aid in isolating RS 232 co...

Page 5: ...with a current rating compatible with the anticipated input current Line cords available as accessories are listed in Table 3 Plug the source power connector into the source power inlet connec tor at...

Page 6: ...put for use with SCPI TRG and TRIG commands Refer to Operator s manual for details GPIB CONNECTIONS Your computer must have a GPIB interface card installed Connect the power supply to the computer s G...

Page 7: ...port located on the rear panel See Fig ure 3 A Null Modem cable is not required for older MAC computers with D sub serial port in which the RXD and TXD line transposition is accomplished via external...

Page 8: ...tem on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally offer t...

Page 9: ...n1 Admin2 or Unprotected Series Parallel Configuration Standalone Parallel Series Master 2X2 Master 3X2 for parallel or series Unit Type Stand alone Master 1 to 4 Slave 1 to 5 and Connection Type show...

Page 10: ...R CURRENT AND ASSOCIATED PROTECT LIMITS From the power up screen the settable voltage current parameters are displayed at the bottom of the LCD above the HELP message Use Y or U to highlight the main...

Page 11: ...rmine the maximum value of voltage or current that can be programmed 1 Press from the power up screen to enter the General Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Sett...

Page 12: ...nabled the pre existing settings for volt age current protect and voltage limit are restored WARNING For both inductive loads and con stant current type active electronic loads when the BOP output is...

Page 13: ...F For con stant voltage type active electronic loads this mode stops energy flow during the OFF state Table 5 indi cates how the power supply responds to a command to go from Output ON to OFF CONFIGUR...

Page 14: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Page 15: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Page 16: ...16 228 1692 REV 3 112113 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...

Reviews: