I — DESCRIPTION.

The BOP 1KW-MG Series hereafter referred to as
BOP, are true 4-quadrant programmable voltage and
current power supplies, meaning they are capable of
both sourcing and sinking power (see Figure 1).
These bipolar power supplies pass smoothly
through zero without switching to provide true ± volt-
age and ± current. These BOP power supplies use
switch mode technology for low dissipation. A bi-
directional, isolating, a-c input power factor correct-
ing (PFC) circuit recuperates energy sinked from an
active load and sends it back into the line to maintain
low dissipation.
These BOP power supplies are controlled digitally
from a menu-driven front-panel keypad or one of the
standard remote digital interfaces (GPIB or RS 232)
to set voltage and current and the four protection

limits (+voltage, –voltage, +current and –current.) A
front panel rotary adjuster allows real-time adjust-
ment of the output. A large LCD displays the mode
of operation, the settings, and the actual output volt-
age and current. Additionally, these BOP models
can be remotely controlled by an analog ±10V input
for the main channel (voltage or current), and a +1 to
+10V input for the limit channels. 
BOP models are suitable for driving inductive loads
such as large magnets or motors, and for exercising
batteries. They are also suitable for characterizing
solar cell arrays, and powering many electrochemi-
cal reactions.
.

II — UNPACKING.

This instrument has been thoroughly inspected and
tested prior to packing and is ready for operation.
After careful unpacking, inspect for shipping damage
before attempting to operate. Perform the “Prelimi-
nary Operational Check.” on page 5. If any indication

of damage is found, file an immediate claim with the
responsible transport service.

III — EQUIPMENT SUPPLIED

.

 

See Table 2.

TABLE 1.  BOP 1KW-MG MODEL PARAMETERS

Model

d-c Output Range

Closed Loop Gain

Output Impedance

Voltage

(V d-c)

Current

(A d-c)

Voltage 

Channel

G

V

 (V/V)

Current 

Channel

G

I

 (A/V)

Voltage Mode

(Series R - L)

Current Mode

(Parallel R - C)

R

d-c

(mOhms)

L

(

µ

H)

R

d-c

(Ohms)

C

(

µ

F)

1000 WATT MODELS

BOP 6-125MG

0 to ±6

0 to ±125

0.6

12.5

0.05

1.5

24

1150

BOP 10-100MG

0 to ±10

0 to ±100

1.0

10.0

0.1

2.0

50

1100

BOP 10-75MG

0 to ±10

0 to ±75

1.0

7.5

0.13

2.0

67

976

BOP 20-50MG

0 to ±20

0 to ±50

2.0

5.0

0.40

8.3

200

371

BOP 25-40MG

0 to ±25

0 to ±40

2.5

4.0

0.63

15.8

313

165

BOP 36-28MG

0 to ±36

0 to ±28

3.6

2.8

1.30

25

640

103

BOP 50-20MG

0 to ±50

0 to ±20

5.0

2.0

2.50

50

1250

55

BOP 72-14MG

0 to ±72

0 to ±14

7.2

1.4

5.14

104

2570

33

BOP 100-10MG

0 to ±100

0 to ±10

10.0

1.0

10.0

163

5000

16

NOTE:  When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the 

BOP. Otherwise the overvoltage protection will shut down the power supply.

TABLE 2.  EQUIPMENT SUPPLIED

ITEM

FUNCTION

PART NUMBER

Source Power Entry mating connector

Mates with source power entry connector

 142-0381 (Kepco) (IEC 320)

PAR/SER CONTROL - IN 
mating connector

Mates with PAR/SER CONTROL - IN port to allow 
access to pins required for calibration

142-0488 (Kepco)

Summary of Contents for BOP 10-100MG

Page 1: ...inted as a handy reference The BOP 1KW MG Operator s Manual also includes a full description of the digital interfaces and the SCPI command language FIRMWARE VERSION Refer to www kepcopower com suppor...

Page 2: ...cell arrays and powering many electrochemi cal reactions II UNPACKING This instrument has been thoroughly inspected and tested prior to packing and is ready for operation After careful unpacking insp...

Page 3: ...112113 228 1692 REV 3 3 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 4: ...to DTE equipment and one with female pins to connect to a PC personal com puter two RS 232 Loop Back test Connectors one 6 pin and one 8 pin to test RS 232 communication and aid in isolating RS 232 co...

Page 5: ...with a current rating compatible with the anticipated input current Line cords available as accessories are listed in Table 3 Plug the source power connector into the source power inlet connec tor at...

Page 6: ...put for use with SCPI TRG and TRIG commands Refer to Operator s manual for details GPIB CONNECTIONS Your computer must have a GPIB interface card installed Connect the power supply to the computer s G...

Page 7: ...port located on the rear panel See Fig ure 3 A Null Modem cable is not required for older MAC computers with D sub serial port in which the RXD and TXD line transposition is accomplished via external...

Page 8: ...tem on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally offer t...

Page 9: ...n1 Admin2 or Unprotected Series Parallel Configuration Standalone Parallel Series Master 2X2 Master 3X2 for parallel or series Unit Type Stand alone Master 1 to 4 Slave 1 to 5 and Connection Type show...

Page 10: ...R CURRENT AND ASSOCIATED PROTECT LIMITS From the power up screen the settable voltage current parameters are displayed at the bottom of the LCD above the HELP message Use Y or U to highlight the main...

Page 11: ...rmine the maximum value of voltage or current that can be programmed 1 Press from the power up screen to enter the General Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Sett...

Page 12: ...nabled the pre existing settings for volt age current protect and voltage limit are restored WARNING For both inductive loads and con stant current type active electronic loads when the BOP output is...

Page 13: ...F For con stant voltage type active electronic loads this mode stops energy flow during the OFF state Table 5 indi cates how the power supply responds to a command to go from Output ON to OFF CONFIGUR...

Page 14: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Page 15: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Page 16: ...16 228 1692 REV 3 112113 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...