10
228-1692 REV 9
062119
KEPCO, INC.
131-38 SANFORD AVENUE
FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000
FAX (718) 767-1102
www.kepcopower.com
email: [email protected]
for sine and triangle, Repeat (initial/
repeat)
•
#
- Display
•
•
Display Settings:: Graphic Display
(
meters
/graphics, background (
black
/
white/monoblack/blue/green/lt.green/
lt.blue), Protect Entry (
independent
/bipo-
lar) Waveform Stop (
output OFF
/User
Option), Key Press beep (
On
/Off/Error
only)
•
$
- Analog Remote Setup
•
•
Analog Remote Settings: Reference input
(
internal
/external/external reference
level), protect limit (
Internal
/External/Les-
serLimit), external mode (
disable/
enable)
•
%
- General Setup
•
•
Interface Settings:
•
•
•
*RST set Output (
on
/off),
•
•
•
GPIB Settings: Language (
SCPI
/CIIL),
GPIB address (default =
6
), Device
clear (
SCPI
/MATE)
•
•
•
Serial Settings: Baudrate (
Off
/9600/
19200/38400), Xon/Xoff (
disable
/
enable), prompt (
disabled/echo/
enabled/enab+echo)
•
•
•
LAN Settings: IP Address, IP MASK,
AUTO IP
ON
, DHCP
ON
, Name and
index (MDNS name)
•
•
Max/Min Settings: for voltage mode: +Volt-
age max, –Voltage min, ±CProtect max/
min; for current mode: +Current max,
–Current min, ±VProtect max/min
•
•
Load Type:
Active
/Resistive/Battery,
Remote On-off: (disabled/high is off/low is
off/high is on/low is on/LowPulseOff)
•
•
Standby Pin Operation:
LowPulse
, HighI-
sOn, LowIsOn, HighIsOff, LowIsOff, Dis-
abled
•
•
Revisions/Test: (Tests: display, keypad,
LAN, interface, serial, analog and output)
•
•
Calibration: Voltage, Current and External
and Controls calibration. Shows Firmware
versions for Display, Serial, GPIB, LAN
and analog.
•
•
Power-up Settings: Mode (
Voltage
/Cur-
rent/External), Main channel Reference
(
Internal
/External/ExtlRefLev), main set-
ting, Protection: Type (
Internal
/External/
LesserLimit), Voltage Limit (current mode),
Current Level (voltage mode), output
ON
/
OFF
•
•
Password
•
•
•
Password Settings: Menu protection
(Interface/Max-Min/Load/Test/Calibra-
tion/Power-up/Keypad @ local/Key-
pad@power-up), Save Display Change
(Enable/
Disable
), Passwords (Unpro-
tected/Main/Admin1/Admin2)
•
•
Series/Parallel: Configuration (Standalone/
Parallel/Series/Master 2X2/Master 3X2);
for parallel or series: Unit Type (Stand-
alone/1 to+4/Slave #1 to #4) and
Configuration: shows Series or Parallel).
FIGURE 5. POWER-UP SCREEN SHOWING GRAPHIC METERS
HOW TO MODIFY A PARAMETER.
First access the parameter by accessing the proper
menu as described above. To modify a parameter
listed in a menu or submenu, proceed as follows:
1. Highlight the parameter using the
Y
and
U
keys.
2. When the desired choice is highlighted, press
!
to modify the active setting. The choices are dis-
played with the active setting highlighted. In the
case of numerals, the units digit is highlighted.
•
To change a numeric setting, press the num-
ber keys, then press
ENTER
to program the
numbers entered. Use the
CLEAR key
to
clear numbers entered and start over. The
ADJUST
control can also be used to incre-
VOLTAGE
SOURCE
0.0402
0.0000
ANALOG VOLTMETER
DIGITAL VOLTMETER
ANALOG AMMETER
DIGITAL AMMETER
HIGHLIGHT TO CHANGE
LOCAL/REMOTE
OPERATING
INFORMATION
SOFTWARE
FUNCTION KEY
DESCRIPTIONS
STATUS
ACTIVE SETTINGS
MESSAGES
VOLTAGE
0000
0.