1-2
BHK-MG (OPR) 032816
TABLE 1-1. MODEL PARAMETERS
MODEL
NUMBER
OUTPUT
VOLTAGE
RANGE
(VOLTS)
OUTPUT
CURRENT
RANGE
(mA)
MAXIMUM
OUTPUT
POWER
(WATTS)
OUTPUT EQUIVALENT IMPEDANCE (FAST MODE)
VOLTAGE MODE
(SERIES R–L)
CURRENT MODE
(PARALLEL R–C)
Rd-c (Ohms)
L (mH)
Rd-c (MOhms)
C (
F)
BHK 300-0.6MG
0 - 300
0 - 600
180
0.025
2.0
3.33
0.013
0 - 60
18
33.3
0.008
BHK 500-0.4MG
0 - 500
0 - 400
200
0.0625
3.6
8.3
0.012
0 - 40
20
83
0.007
BHK 1000-0.2MG
0 - 1000
0 - 200
200
0.25
6.0
33
0.005
0 - 20
20
333
0.003
BHK 2000-0.1MG
0 - 2000
0 - 100
200
1.0
35
133
0.002
0 - 10
20
1333
0.001
TABLE 1-2. BHK-MG 200W SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION
INPUT CHARACTERISTICS
a-c Voltage
nominal (switch selectable) 115/230V a-c
Single phase
range (switch selectable) 105-125/210-250V a-c
Frequency
nominal 50-60Hz
range 47-63Hz
Current
115V a-c 4.0A a-c
200W at output
230V a-c 2.1A a-c
OUTPUT CHARACTERISTICS
NOTE: Current specifications contained in this table refer to source current (delivered by the unit to the load). Sink current (absorbed
by the unit from the load) occurs when the output voltage is programmed to a lower value. The sink current is constant, from
45% to 55% of High Current scale rating; it flows until the output reaches the lower voltage.
Type of Stabilizer
Linear with automatic
crossover
Voltage/Current
Adjustment range
(Adjustment is either continu-
ous using analog program-
ming, or stepped using digital
programming)
Voltage 0 to 100% of rating
See PAR. 1.4.2.2 and 1.4.2.3 for details
about analog programming and readback.
Use Menu program to change current
scale (See PAR 3.2.10)
Current 0-100% of rating,
or 0-10% of rating
Digital Programming
resolution
Voltage and Current 0.025% of rating
Current measurement requires calibrated
shunt (see PAR. 4.2)
Digital Programming accuracy
Voltage 0.025% of rating
Current 0.05% of rating
Both current scales
Digital Data Readback
accuracy
Voltage 0.05% of rating
Current 0.05% of rating
Both current scales, 10-100% of rating
0.005% of rating
Both current scales, <10% of rating (auto-
matic 10X magnifier)
Source effect
Voltage 0.001% E
O
max
Input voltage
105-125/210-250V a-c
Current 0.002% I
O
max
Load effect
Voltage 0.005% E
O
max
no load - full load
Current 0.015% I
O
max
short - full load
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......
Page 154: ......