 key erases data entered). Press ENTER to accept new

setting, or CLEAR to exit without changing setting. 

NOTE: Blinking equal sign is indicated by   in this manual.

4.2.3.  DISPLAY (LCD). 

The LCD is a 2-line display with a

capacity of 16 characters per line. The information is gen-
erally arranged as follows (information that does not follow
this format is self-explanatory): At top left: 

Loc/Rem

 indi-

cates Local or Remote status. At top right: 

CV/CC

 indi-

cates Constant Voltage or Constant Current mode. At
bottom left: 

n.nnnV

 indicates output voltage if in com-

mand entry or 

(parameter

)

 (e.g. 

OVset

 if 

OV SET

 key

was pressed) if in data entry. Bottom middle shows 
(blinking “

:

”) for command entry or   (blinking “

=

”) for data

entry. At bottom right: 

n.nnnA

 indicates output current in

command entry, or, in data entry, 

n.nnn

 indicates the

present value of the parameter indicated at the bottom left
(the present value is replaced by data entered).

4.2.4.  KEYPAD FUNCTIONS. 

(Refer to Figure 1.) Six

keys have dual functions, depending on whether the
power supply is in command entry status (waiting for a
command to be entered), or data entry status (waiting for
a number to be entered). Command entry status is
indicted on the LCD by a blinking colon   and data entry
status is indicated by a blinking equal sign  .

NOTE: Keys with dual functions are labeled with both a

command and a number. The command label is
referred to when the unit is in   command entry
status; the number is referred to when the unit is
in   data entry status.

OUTPUT ON/OFF

 - 

Command Entry   active:

If bottom line of LCD reads 

Output OFF

, press to

enable the output. If output is on (voltage and current
measurements displayed on bottom line of LCD), press to
disable the output.

V SET

 - 

Command Entry   active:

Press to set output voltage. After 

V SET

 is pressed,

previous setting is displayed. Data entry required to enter
new value of output voltage; press 

ENTER

 to accept dis-

played value.

I

 SET

 - 

Command Entry   active:

Press to set output current. After 

I

 SET

 is pressed,

previous setting is displayed. Data entry required to enter
new value of output current; press 

ENTER

 to accept dis-

played value.

LOCAL

 - 

Command Entry   active:

If the power supply is in remote mode, keypad is dis-

abled except for 

LOCAL

 key. Press to enable keypad. If

LCD reads 

KEYPAD LOCKED

, The 

LOCAL

 key is disabled

and can only be unlocked by remote operation.

RESET

 - 

Command Entry   active:

Press to restore the power on default values: CV

mode, output voltage = 0, output current = minimum (1-
2% of 

I

O

max), output enabled, overvoltage and overcur-

rent values. Also resets overvoltage or overcurrent condi-
tion.

MENU

 - 

Command Entry   active:

Press to enter Menu commands: press repeatedly to

scroll through Menu functions: (1) set LCD contrast, (2)
GPIB address, (3) DCL Control, (4) Speaker on/off, (5)
Calibration password, (6) previous calibration values, (7)
factory calibration values, (8) view firmware serial number,
(9) set maximum voltage, (10) set maximum current, (11)
protection delay. Press 

ENTER

 or 

RESET

 to exit Menu.

OV SET / 7

Command Entry   active:

 Press to set overvoltage

protection value. Data entry required to enter the overvolt-
age protection value; press 

ENTER

 to accept displayed

value.

Data Entry   active:

 Press to enter number 7.

OC SET / 8

Command Entry   active:

 Press to set overcurrent

protection value. Data entry required to enter new over-
current protection value; press 

ENTER

 to accept dis-

played value.

Data Entry   active:

 Press to enter number 8.

CALIB / 9

Command Entry   active:

 Press to enter Calibration

status. Requires password entry; instructions appear on
LCD.

Data Entry   active:

 Press to enter number 9.

STORE

 - 

Command Entry   active:

Press to store present values of output voltage and

current and overvoltage and overcurrent protection. Data
entry required to select memory location where values are
to be stored

EDIT PROG

 - 

Command Entry   active:

Press to select the starting memory location to be

edited. Then use 

 or 

 to view or modify the parame-

ters of a specific memory location or to create a new pro-
gram.

STEP / 4

Command Entry   active:

 Press to select starting

address of program to be executed one step at a time.

Data

 Entry   active:

 Press to enter number 4.

Summary of Contents for ATE-DMG

Page 1: ...modes Slow mode operation is recommended for applications demanding a constant volt age source Fast mode operation is best if the output volt age must change rapidly either in response to an external...

Page 2: ...test is successful the following indica tions are visible a The alphanumeric display LCD indicates the model and GPIB address b After approximately 2 seconds the display changes to the power on defaul...

Page 3: ...ue or if the power supply is pro grammed with step functions square wave pulse etc and maximum dynamic performance is expected Set the unit to fast mode by referring to the full Operator Manual see PA...

Page 4: ...t voltage that can be supported between either output terminals and chassis ground is 500V d c or peak Either side of the output may be grounded A resistor capacitor network is connected from the nega...

Page 5: ...press ENTER 3 Depress the DISABLE button and keep it depressed white turning the LEVEL control counterclockwise until the CROWBAR indicator energizes simulated crowbar action 4 With the DISABLE butto...

Page 6: ...to accept dis played value I SET Command Entry active Press to set output current After I SET is pressed previous setting is displayed Data entry required to enter new value of output current press E...

Page 7: ...Command Entry active In CV constant voltage press to increase output volt age by increment equal to voltage resolution 0 025 of EOmax In CC constant current press to increase output cur rent by increm...

Page 8: ...he key is pressed Press ENTER or CLEAR to exit without changing setting Enter new value the key erases data just entered and press ENTER to accept new setting or CLEAR to exit without changing setting...

Reviews: