USER MANUAL
4 OPERATION PROCEDURES
4.1 First use
If the Tracer was stored at low temperatures, it shall be kept at the
operating temperature for no less than 1 hour before use.
Take the Tracer out of its case and examine protective covers and
fasteners. Check the Tracer body and external power supply unit for
the mechanical damage.
WARNING!
Always observe safety rules when you work with live cables.
Do not apply voltage of more than 42V to the open metal parts or
jacks of the Tracer.
The Tracer locates utilities and cable faults by the induction method.
Replacement sensors facilitate finding damaged insulation by the
voltage of current bleeding via the ground.
The alternating magnetic field induced by the utility and/or the
voltage generated in the replacement sensors are transformed into a
signal form. This signal is amplified and processed by the digital
signal processor. Then the signal levels are displayed in a form of
line bars and digital values in dB or Volts. The indication may be
supported with the audible signal.
4.2 Battery charging
The Ni-Mh batteries of the 5H-AA 2000B-1 type with the rated
capacity of 2000mA∙h are used to supply the device.
WARNING!
Before charging, make sure that a rechargeable battery is put into
the battery compartment. If the battery case contains non-
rechargeable batteries when charging, this may cause damage to
the Tracer.
The ambient temperature shall be from plus 10 ºС to plus 30 ºС
when charging. Charging at other temperatures may reduce battery
life.
Charging rate is displayed as a battery icon.