5.0 Specifications
MMI-2xx: 12 (320 mA) to 24 (160 mA) VDC (3.8 W)
unregulated, Maximum voltage limits 8 to 30 VDC.
MMI-2xxA: 115 VAC +10% 50/60Hz (36 mA)
MMI-2xxB: 230 VAC +10% 50/60Hz (17 mA)
Power
Open Collector
Output
250 mA maximum at 3 to 36 VDC non-inductive load
MMI-200, 210, 220 (std): 8 K Byte EEPROM
Memory
MMI-210(opt.), 220(opt.): 32 K Byte EEPROM
MMI-240 (std.): 32 K Byte EEPROM
Temperature
VFD Type: 32 to 140 °F (0 to 60 °C)
LCD Type: 32 to 122 °F (0 to 50 °C)
Display
MMI-200 - None
PC Port
Communications
Serial RS232 output during operation
Selectable 7 or 8 bit; Odd, Even or No Parity;
1 Start; 1 Stop bit; No handshake; 300, 600, 1200, 2400,
4800, 9600 or 19200 Baud.
Default PC Port Communications:
9600 Baud, 8 bits, Parity = None.
Note: Serial PC Port communication specifications apply to
MMI printer setup and do not affect PC to MMI or Controller to
MMI communications.
Bezel
RS232; SMIC Adapter cable required. Communications param-
eters are Controller dependent and use factory default settings
of the specific PLC in use.
Membrane Keypad with tactile feedback; Rated NEMA 4X
(water tight) provided it is installed with gasket provided as per
installation instructions.
MMI-210, 220 - Vacuum Fluorescent or backlit LCD;
2 Lines of 20 characters each; Character height is 0.2"
MMI-240 - Vacuum Fluorescent or backlit LCD;
4 Lines of 20 characters each; Character height is 0.2"
Bezel: 6" H x 8" W
Panel Cutout: 7.1"(180mm) W X 5.1"(129mm) H x 3.0"(76mm)
D
Clearance depth required below unit: approximately 3.0"(76mm)
depending on cable connectors.
Dimensions
SMIC Port