19
X08-3280-10 (3/3)
U
W
Y
V
X
VRS-7100
3
SD
1
2
FM DET
STETEO
5
7
9
11
13
4
6
T MUTE
S LEVEL
PLL DO
PLL CLK
8
PLL DIN
PLL CE
BDS SCL
BDS SDA
SEL DATA
SEL CLK
SEL ST
10
12
14
15
17
21
19
BDV SDA
BDV SCL
HP RLY
HP MUTE
16
18
VDD FAN
NC
20
PRE MUTE
R864 100K
R865 100K
R866 100K
R867 100K
C709 1000P
R858 100K
R860 100K
R856 100K
R840 470
R836 100
R837 100
R838 100
R839 470
R841 100
R842 100
R843 1K
R921 100
R922 100
R923 100
R924 100
R925 100
5
YCbCr V2/DVD
15
13
9
7
11
14
12
HP DET
V DET
CVBS SW1
CVBS SW2
10
6
8
CVBS SW4
CVBS SW5
S SW2
S MUTE
S SW1
CVBS SW3
3
1
V DATA
4
2
YCbCr MUTE
V ST
V CLK
17
F
R863 100K
R832 100K
R855 100K
R859 100K
R926 100
R927 100
R928 100
R929 100
R930 100
R831 100
R938 100
R936 100
R937 100
R888 100
R884 100
R885 100
R886 100
R887 100
11
Y8
GND
10
12
9
Y7
A8
19
18
17
16
15
14
13
OE2
Y1
Y2
Y3
Y4
Y5
Y6
A1
A2
A3
A4
A5
A6
A7
2
3
4
5
6
7
8
20
1
VCC
O
E1
R848
4.7
C711
1000P EARTH
1
2
FLPDRV CS
FLPDRV CLK
4
5
3
LED 1
FLPDRV MISO
FLPDRV MOSI
6
11
13
7
8
9
10
12
LED 2
ED STANDBY
REMOTE
KEY STANDBY
KEY BAND
ENC VOL CCW
ENC VOL CW
VDD3 MICOM
15
14
16
GND FLRETURN
VDD5 MICOM
GND
19
18 FILAMENT-
VDD FL
R862 100K
R854 100K
R852 100K
R861 100K
R857 100K
R835 100K
R834 100K
R833 100K
81
82
83
84
85
86
87
88
89
90
91
92
93
94
96
97
98
15
16
17
18
13
12
11
21
23
24
36
2.2
R896
0.01
C802
18
19
20
6
4
5
29
26
78
77
63
17
22
25
18
15
16
79
12
13
11
7
92
8
93
88
94
89
96
90
97
91
98
18
17
16
12
14
13
11
57
56
59
69
70
75
74
66
15
11
12
13
14
15
16
17
18
2.2
R895
AUDIO C/(SW/CS)
TAS ERR RCVY
TAS SHUTDOWN
4
3
2
1
VDD4
GND
AUDIO FCLK
6
5
7
GND
AUDIO MCLK
AUDIO BCLK
VCC ANALOG
9
GND
8
AUDIO L/R
14
13
12
11
10
DC PROT.
VDD FAN
GND FAN
AUDIO LS/RS
16 TAS SDA
TAS SCL
15
17 TAD PDN
19
18 TAS MUTE
21
20 TAS RST
85
83
86
84
82
81
87
94
86
87
64
65
80
1000P
C24
R872
4.7K
R873
4.7K
4
6
63
+3.9V
+3.4V
+3.4V
+3.4V
+5V
+5V
+5V
+5V
+5V
33.4V
CN71
Q701
CN72
CN74
CN13
CN1
X07-
4/5
X14-C/7-
5/5
CN101
2/5
CN309
X25-A/2-
3/5
X25-B/2-
CN7
LEVEL
(+3V
SHIFTER
+5V)
+5V)
LEVEL SHIFTER
(+3V
(X08-3280-10)
VRS-7100 (1/5)
IC82
CAUTION:
For continued safety, replace safety crit-
ical components only with manufacturer's recom-
mended parts (refer to parts list).
indicates safety
critical components. For continued protection
against risk of fire, replace only with same type and
rating fuse(s). To reduce the risk of electric shock,
leakage-current or resistance measurements shall
be carried out (exposed parts are acceptably insu-
lated from the supply circuit) before the appliance is
returned to the customer.
The DC voltage is an actual reading measured with
a high impedance type voltmeter with no signal
input. The measurement value may vary depending
on the measuring instruments used or on the prod-
uct.
BE-6
AD-2
AM-4
AO-3
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299