Field Programming Reference (FPRG)
36
6 EDIT MENU
"
Save Delay Timer A
This is a duration between the time when an Auxiliary
Input port or an PF key assigned to the Display On
function receives a signal and the time when the LED
is switched Off or the AF Amp is switched Off while the
TKR-750/850/751/851
is in Power Saver Mode.
Configure the duration by the spin buttons or directly
enter the value to configure the duration.
(Refer to 6.5 Key Assignment Window.)
(Refer to Table 6.10 Function Port Window.)
Note:
The Power LED does not unlit even if the Display On
function is activated.
"
Save Delay Timer B
This is a duration between the time when the
TKR-750/
850/751/851
enters Power Saver Mode and the time
when the Power Saver function is switched On
(Display Off). You can also configure the duration from
the time when the
TKR-750/850/751/851
switches from
Busy status to Not Busy status to the time when it
enters Save On status. Configure the durations by the
spin buttons or directly enter the value to configure the
durations.
"
Save Mode Duration
This is a duration between the time when the
TKR-750/
850/751/851
enters Power Saver Mode and the time
when it automatically exits the Mode. Configure the
duration by the spin buttons or directly enter the value
to configure the duration.
"
Save On Function
It can configure the function to activate when the
TKR-
750/850/751/851
enters Power Saver Mode. You can
assign three functions and they operate in order of
1st, 2nd, then 3rd. Select the function from the
dropdown list.
"
Save Off Function
It can configure the function to activate when the
TKR-
750/850/751/851
exits Power Saver Mode. You can
assign three functions and they operate in order of
1st, 2nd, then 3rd. Select the functions from the
dropdown list.
"
Start Up
It can configure the function to activate when the
KR-
750/850/751/851
is turned ON. You can assign three
functions and they operate in order of 1st, 2nd, then
3rd. Select the functions from the dropdown list.
"
Backup Power Function
It can configure the function to operate when the
power of the
KR-750/850/751/851
is switched from the
main power to the backup power. You can configure
three functions and they operate in order of 1st, 2nd,
then 3rd. Select the functions from the dropdown list.
"
Main Power Function
It can configure the function to operate when the
power of the
KR-750/850/751/851
is switched from the
backup power to the main power. You can configure
three functions and they operate in order of 1st, 2nd,
then 3rd. Select the functions from the dropdown list.
Range
1 - 255 sec.
In steps of
1 sec.
Default
10 sec.
Range
10 - 480 min.
In steps of
10 min.
Default
240 min.
Range
Off, 0.5 - 24 h
In steps of
0.5 h
Default
Off
Range
Refer to Table 6-2 Available functions.
Default
None
Range
Refer to Table 6-2 Available functions.
Default
None
Range
Refer to Table 6-2 Available functions.
Default
None
Range
Refer to Table 6-2 Available functions.
Default
None
Range
Refer to Table 6-2 Available functions.
Default
None