ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
56
TK-885
11. DTMF
1) Set test mode
Power meter Rear
ANT
1.5kHz (Narrow)
±
0.1kHz (Narrow)
deviation
Select “DTMF” in tuning mode. Deviation
panel
3.0kHz (Wide)
±
0,2kHz (Wide)
Deviation meter filter
meter
LPF : 15kHz
Oscilloscope
HPF : OFF
PTT : ON
AF VTVM
Front
MIC
AG
panel
2) “w DTMF”
PTT : ON
12. FFSK
1) Set test mode
1.5kHz (Narrow)
±
0.1kHz (Wide/Narrow)
deviation
Select “FFSK” in tuning mode.
3.0kHz (Wide)
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
2) “w FFSK”
PTT : ON
13. TONE
1) Set test mode
1.5kHz (Narrow)
±
0.1kHz (Wide/Narrow)
deviation
Select “TONE” in tuning mode.
3.0kHz (Wide)
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
2) “w TONE”
PTT : ON