55
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-880
11. DTMF
1) Set test mode
Power meter Rear
ANT
3.0kHz (Wide 5k)
±
0.2kHz (Wide 5k/Wide 4k)
deviation
Select “n DTMF” in tuning mode. Deviation
panel
2.4kHz (Wide 4k)
±
0.1kHz (Narrow)
Deviation meter filter
meter
1.5kHz (Narrow)
LPF : 15kHz
Oscilloscope
HPF : OFF
PTT : ON
AF VTVM
Front
MIC
AG
panel
2) “s DTMF”
PTT : ON
3) “w DTMF”
PTT : ON
12. FFSK
1) Set test mode
3.0kHz (Wide 5k)
±
0.1kHz
deviation
Select “n FFSK” in tuning mode.
2.4kHz (Wide 4k)
(Wide 5k/Wide 4k/Narrow)
Deviation meter filter
1.5kHz (Narrow)
LPF : 15kHz
HPF : OFF
PTT : ON
2) “s FFSK”
PTT : ON
3) “w FFSK”
PTT : ON
13. TONE
1) Set test mode
3.0kHz (Wide 5k)
±
0.1kHz
deviation
Select “n TONE” in tuning mode.
2.4kHz (Wide 4k)
(Wide 5k/Wide 4k/Narrow)
Deviation meter filter
1.5kHz (Narrow)
LPF : 15kHz
HPF : OFF
PTT : ON
2) “s TONE”
PTT : ON
3) “w TONE”
PTT : ON