TK-8302/8302H
50
To make measurements in the RF section, connect the RF level meter.
In the RF section, use a 0.01μF coupling capacitor.
(The display shows the SSG input value required to obtain 12dB SINAD.)
To make measurement in the AF section, connect the AC level meter.
(ANT input: –53dBm, 1kHz FM, 3kHz Dev (WIDE) / 1.5kHz (NARROW))
The AF output level is adjusted for a 0.47V/4ohm by the front panel AF VOL control.
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
To make measurements in the RF section, connect the RF Wattmeter (50ohm).
ANT
BPF
BPF
LNA
Q506
Mixer
Q504
MCF
XF500
FM IC
IC500
38.85MHz
CF500/
CF501
450kHz
16
9
IC705
J701
16
26
AF Frequency (1kHz)
1
10
0.57Vrms
12mVrms
4.2mVrms 0.47mVrms
IC701
Baseband
IC
IC701
Baseband
IC
17
16
0.256Vrms
Center Frequency
IF AMP
Q502
W: –121dBm
N
: –121dBm
W: –121.5dBm
N
: –121.5dBm
W: 153.6mVrms
N
: 76.9mVrms
W/N
61.2mVrms
W/N
61.2mVrms
W: –106dBm
N
: –106.5dBm
W: –106.5dBm
N
: –107dBm
W: –103dBm
N
: –103dBm
W: –119.5dBm
N
: –120dBm
W: –91dBm
N
: –92dBm
W: –95dBm
N
: –96.5dBm
0.18Vrms
IC700
IC701
IC701
Q6
Q9
Q10
–12dBm
Display Unit
X54-367
TX-RX Unit
G1
D
G1
D
2
1
21
20
21 24
Q300
IC301
D719
ANT
D302
D303
TX-RX Unit (VCO)
TX-RX Unit
Power Module
TX-RX Unit
MIC
5.4dBm
6.2dBm
17dBm
25W
(TK-8302)
45W
(TK-8302H)
3dBm
23dBm
1
4
LEVEL DIAGRAM
Receiver Section
T
ransmitter Section