7
T
RANSMITTING
/ R
ECEIVING
1
Select your desired zone and channel.
2
Press the microphone
PTT
switch and speak into the microphone to transmit. Release the
PTT
switch to receive.
• For best sound quality at the receiving station, hold the microphone approximately
1.5 inches (3 ~ 4 cm) from your mouth.
SCAN
Scan monitors for signals on the transceiver channels. While scanning, the transceiver checks for a
signal on each channel and only stops if a matching signal is present. There are three types of scans
available.
•
Single Scan:
Monitors the channels of only the currently selected zone. If set up to
scan the Priority channel, it will be scanned even if it is not in the zone.
•
Multi Scan:
Monitors the channels of every zone.
•
List Scan:
Monitors the channels within the specified range of zones. If set up to scan
the Priority channel, it will be scanned even if it is not within any of the zones in the list.
To start/stop scanning, press the key programmed as
Scan
.
• “SCAN”
and
the icon appear on the display during scan.
• When a signal is detected, scan pauses at that channel. The transceiver will remain on
the busy channel until the signal is no longer present, at which time scan resumes.
Note:
To use Scan, there must be at least 2 channels added to the scan sequence.
C
HANNEL
R
ECALL
During scan, you can recall the last zone and channel/group ID on which you made a call by pressing
the key programmed as
CH/GID Recall
. Scan will remain paused on the Recall channel until you
press the key again.
P
RIORITY
S
CAN
If a Priority channel has been programmed, the transceiver will automatically change to the Priority
channel when a call is received on that channel, even if a call is being received on a normal channel.
• The icon appears on the display when the Priority channel is selected.
T
EMPORARY
C
HANNEL
L
OCKOUT
During scan, you can temporarily remove specific channels from the scanning sequence by pressing
the key programmed as
Scan Delete/Add
while Scan is paused at the undesired channel. To
temporarily remove a zone, press and hold
Scan Delete/Add
while Scan is paused at a channel in the
undesired zone.
• The channel/zone is no longer scanned. However, when scanning is ended and