background image

10

ADVANCED OPERATIONS

T

IME

-

OUT

 T

IMER

 (TOT)

The purpose of the Time-out Timer is to prevent any caller from using a channel
for an extended period of time.  If you continuously transmit for a period of time
that exceeds the programmed time, the transceiver will stop transmitting and an
alert tone will sound.  To stop the tone, release the 

PTT

 switch.

Your dealer can program a warning function to alert you before the TOT expires.
Continuously transmitting for the time specified by your dealer will cause the
warning tone to sound.

B

USY

 C

HANNEL

 L

OCKOUT

 (BCL)

The Busy Channel Lockout feature is activated or deactivated by your dealer.

When activated, BCL prevents you from interfering with other parties who may be
using the same channel that you selected.  Pressing the 

PTT

 switch while the

channel is in use will cause your transceiver to emit an alert tone and
transmission will be inhibited (you cannot transmit).  Release the 

PTT

 switch to

stop the tone and return to receive mode.

T

ALK

 A

ROUND

You may occasionally experience an interruption in service (due to a power
failure, etc.).  During such an occurence, you can continue communication by
using the Talk Around feature, if it has been programmed by your dealer.
Talk Around allows you to communicate directly with other transceivers, without
the use of a repeater.  However, if the station you want to contact is too far away,
or there are geographical obstacles in the way, you may not be able to contact
the station.

Toggle Talk Around ON and OFF by pressing the key programmed as 

Talk Around

.

• The indicator corresponding to the 

Talk Around 

key lights while the Talk Around function is ON.

• When using Talk Around, the “receive” frequency is used for both transmission and

reception, and the QT/DQT “decode” signalling is used for both encoding and decoding.

M

ONITOR

Press the key programmed as 

Monitor 

to turn the transceiver signalling OFF.

While signalling is OFF, you can hear all signals received on your current
channel.  With signalling ON, you can hear only signals that match the signalling
programmed in your transceiver.  Press the 

Monitor 

key again to return to

normal operation.

Press and hold the key programmed as 

Monitor

 for 2 seconds to listen to weak

signals that you cannot hear during normal operation, and to adjust the volume
when no signals are present on your selected channel.  Press the 

Monitor 

key

again to return to normal operation.

Summary of Contents for TK-7108

Page 1: ...TK 7108 INSTRUCTION MANUAL VHF FM TRANSCEIVER B62 1664 10 M 09 08 07 06 05 04 03 02 01 KENWOOD CORPORATION TK 8108 UHF FM TRANSCEIVER ...

Page 2: ...iver is mounted in the trunk area INJURY FROM RADIO FREQUENCY TRANSMISSIONS Do not operate your transceiver when somebody is either touching the antenna or standing within two to three feet of it to avoid the possibility of radio frequency burns or related physical injury DYNAMITE BLASTING CAPS Operating the transceiver within 500 feet 150 m of dynamite blasting caps may cause them to explode Turn...

Page 3: ... THE VOLUME 6 SELECTING A CHANNEL 6 TRANSMITTING 6 RECEIVING 6 SCAN 7 TEMPORARY DELETE 7 REVERT CHANNEL 7 DTMF CALLS 8 MANUAL DIALLING 8 STORING DTMF NUMBERS 8 DIALLING STORED DTMF NUMBERS 8 CLEARING STORED DTMF NUMBERS 8 REDIALLING 8 CODE SQUELCH ID CODE 9 RECEIVING 9 TRANSMITTING 9 ADVANCED OPERATIONS 10 TIME OUT TIMER TOT 10 BUSY CHANNEL LOCKOUT BCL 10 TALK AROUND 10 MONITOR 10 EMERGENCY OPERAT...

Page 4: ...hipment file a claim with the carrier immediately SUPPLIED ACCESSORIES m e t I r e b m u N t r a P y t i t n a u Q e l b a c r e w o p C D X X 9 3 3 3 0 3 E 1 A 0 1 e s u F X X 6 1 0 0 1 5 F 2 t e k c a r b g n i t n u o M X X 2 6 6 0 9 2 J 1 t e s w e r c S X X 5 9 3 0 9 9 N 1 s e c e i p 4 w e r c s g n i p p a t f l e S s e c e i p 4 r e h s a w h t i w w e r c s d e d a e h x e H s e c e i p 4...

Page 5: ... following tools are required for installing the transceiver 6 mm 1 4 inch or larger electric drill 4 2 mm 5 32 inch drill bit for the self tapping screws Circle cutters POWER CABLE CONNECTION The transceiver operates in 12 V negative ground systems only Check the battery polarity and voltage of the vehicle before installing the transceiver 1 Check for an existing hole conveniently located in the ...

Page 6: ...tenna and the supplied power cable to the transceiver 3 Slide the transceiver into the mounting bracket and secure it using the supplied hex headed screws 4 When using an optional microphone mount the microphone hanger in a location where it will be within easy reach of the user The microphone and microphone cable should be mounted in a place where they will not interfere with the safe operation o...

Page 7: ...mmable Function key The default setting of this key is Monitor page 10 Other programmable functions available for this key are listed below y y y y y 1 2 3 4 keys Press to select a channel from 1 to 4 When using the Group function press to select a channel from 5 to 8 u u u u u Microphone jack Insert the microphone plug into this jack the microphone is an optional accessory i i i i i Speaker Inter...

Page 8: ...h t n o d e t c e t e d s i l a n g i s a n e h w s t h g i L s i y e k g n i d n o p s e r r o c s t i o t n o d e m m a r g o r p n o i t c n u f e h t e l i h w s t h g i L d e t a v i t c a s i y e k g n i d n o p s e r r o c s t i o t n o d e m m a r g o r p n o i t c n u f e h t e l i h w s t h g i L d e t a v i t c a 8 5 r o 4 1 l e n n a h c d e t c e l e s y l t n e r r u c e h t y a l p ...

Page 9: ...channels 1 through 4 press the Group key again Note You cannot use the Group function while operating in Emergency mode TRANSMITTING Note Before transmitting first monitor the channel to make sure it is not already in use 1 Select your desired channel by pressing a channel key 1 4 If the channel is busy wait until it becomes free 2 Press the microphone PTT switch and speak into the microphone Rele...

Page 10: ...r transceiver has been set up a key may have been programmed with the Temporary Delete function If so press and hold that programmed key for approximately 1 second to temporarily remove undesired channels from the scanning sequence This allows you to scan only those channels which you desire After switching the Scan function OFF or switching the transceiver OFF and then ON again the Scan settings ...

Page 11: ...phone keypad You can enter the digits 0 9 A D and When entering you must first press the PTT switch To cancel press any key on the transceiver front panel other than the switch 3 Press the microphone key then enter a memory location number 1 9 If no key is pressed within 10 seconds the transceiver will return to normal operation DIALLING STORED DTMF NUMBERS 1 Press the microphone key 2 Enter the d...

Page 12: ...anspond is programmed an acknowledgment signal is returned to the calling station Transpond does not function when you are called with a Group code Transpond can send an alert tone or a transceiver ID code If Call Alert is programmed an alert tone will sound when the correct code is received TRANSMITTING 1 Press and hold the PTT switch 2 Enter the code of the transceiver you want to call or enter ...

Page 13: ...ccurence you can continue communication by using the Talk Around feature if it has been programmed by your dealer Talk Around allows you to communicate directly with other transceivers without the use of a repeater However if the station you want to contact is too far away or there are geographical obstacles in the way you may not be able to contact the station Toggle Talk Around ON and OFF by pre...

Page 14: ...ed by your dealer the transceiver can remain in Emergency Mode even while the transceiver power is OFF KEY LOCK Press the key programmed as Key Lock to lock the keys of the transceiver Locking the transceiver keys prevents you from accidentally changing the channel and channel settings While key lock is active you can still use the microphone PTT switch the power switch and the Emergency Monitor a...

Page 15: ......

Reviews: