TK-3302
40
)z
H
k
1(
F
A
RF (Center Frequency)
RF (Center Frequency)
–117.5dBm
–117.0dBm
–119.5dBm
–112.0dBm
–118.5dBm
–107.5dBm
200mV
120mV
IF1 (38.85MHz)
IF2 (450kHz)
AF (1kHz)
SP
500mW
C170
C256
Q204
C234
Q203
Q202
XF201
C216
C214
IC201
FM IF
SYSTEM
C390
AQUA-L
IC308
C391
IC309
15mV
rms
100mV
rms
4.1dBm
15.0dBm
36.3dBm
12.4dBm
4.0W
MIC
AQUA-L
IC308
C59
VCO
PLL
C51
C81
C86
RXLO
D10
C109
Q102
Q11
C115
Q103
Q106
C170
T
o
make measurements in the AF section, connect the AC level meter
.
(ANT input: –53dBm, 1kHz FM, 3kHz DEV (Wide 5k).)
In the RF section,use 470pF coupling capacitor
.
(The display shows the SSG input value required to obtain
12dB SINAD without Local Level.)
AG is set to the MIC Input becomes 3kHz DEV
. at 1kHz MOD. (Wide 5k).
T
o
make measurements in the AF section, connect the AC level meter
.
In the RF section, use 470pF coupling capacitor
.
LEVEL DIAGRAM
Receiver Section
T
ransmitter Section