TK-285/(N)
28
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
1. Setting
1) BATT terminal voltage:7.5V
2) SSG Standard modulation
MOD:1kHz, DEV:1.5kHz
2. VCO lock
[Panel Test Mode]
voltage
1) CH-Sig:2-1
Power meter
Panel
ANT
Check
0.8V or more
RX
2) CH-Sig:3-1
DVM
TX-RX
CV (CN14)
4.4V or less
TX
3) CH-Sig:2-1
0.8V or more
PTT:ON
4) CH-Sig:3-1
4.4V or less
PTT:ON
Transmitter Section [Panel Tuning Mode except when Panel TEST Mode is specified.]
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
ADJUSTMENT
1. Frequency
1) Adj item [FREQ]
Power meter
Panel
ANT
Panel
Encoder
Center frequency
Adjust
Adjust [
∗∗∗
]
Am meter
knob
±
100Hz
PTT:ON
(Note:) After replacing the TCXO
(X1), align using KPG-62D.
2. Max Power 1) Adj item [HPOW]
Check
5.2W or more
Check
Adjust [256]
(L, H CH 4.9W)
2) Adj item
[L HPOW]
➞
[L2 HPOW]
➞
[C HPOW]
➞
[H2 HPOW]
➞
[H HPOW]
Adjust [256]
PTT:ON
3. High Power
1) Adj item [HPOW]
Encoder
5.0W
±
0.1W
Adjust
Adjust [
∗∗∗
]
knob
2.2A or less
2) Adj item
[L HPOW]
➞
[L2 HPOW]
➞
[C HPOW]
➞
[H2 HPOW]
➞
[H HPOW]
Adjust [
∗∗∗
]
PTT:ON
4. High Power
[Panel Test Mode]
4.8~5.2W
Check
1) CH-Sig:1-1
Check
2.3A or less
PTT:ON
2) CH-Sig:2-1
PTT:ON
3) CH-Sig:3-1
PTT:ON
5. Low Power 1) Adj item [LPOW]
0.8W
±
0.1W
Adjust
Adjust [
∗∗∗
]
1.0A or less
2) Adj item
[L LPOW]
➞
[L2 LPOW]
➞
[C LPOW]
➞
[H2 LPOW]
➞
[H LPOW]
Adjust [
∗∗∗
]
PTT:ON
6. Low Power [Panel Test Mode]
Check
1) CH-Sig:1-1
Check
0.5~1.5W
Set low power (Push [C])
1.2A or less
PTT:ON
2) CH-Sig:2-1
PTT:ON
3) CH-Sig:3-1
PTT:ON