TK-285/(N)
30
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
Transmitter Section [Panel Tuning Mode except when Panel TEST Mode is specified.]
14.TONE
1) Adj item [TONE]
Power meter
Panel
ANT
Panel
Encoder
1.45kHz
±
0.05kHz
Deviation
Adjust [
∗∗∗
]
Dev meter
universal
knob
Adjust
LPF:15kHz
Oscilloscope
connector
HPF:OFF
AG
PTT:ON
AF VTVM
15.BATT
1) Adj item [BATT]
Power meter
Panel
ANT
Panel
Encoder
After pressing BATT terminal
Detection
Adjust [
∗∗∗
]
DVM
BATT
knob
the PTT switch, voltage:6.2V
Writing
PTT:ON
terminal
confirm that
one predeter-
mined numeric
in the range 1
to 256 appears
and then press
[C] key. That
numeric will be
stored in memory.
16.BATT
[Panel Test Mode]
Check
No blinking of LED
Detection
1) CH-Sig:1-1
Check
BATT terminal voltage:6.5V
PTT:ON
2) BATT terminal voltage:5.7V
Blinking of LED
PTT:ON
Receiver Section [Panel Tuning Mode except when Panel TEST Mode is specified.]
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
1. Sensitivity
1) Adj item [SENS]
SSG
Panel
ANT
Panel
Encoder
Adjust for
14dB SINAD or
Adjust
Adjust [
∗∗∗
]
knob
maximam
more.
SINAD.
2) Adj item
AF VTVM
Universal
Oscilloscope
Connector
[L SENS]
➞
[C SENS]
➞
[H SENS]
Adjust [
∗∗∗
]
SSG OUT:-118dBm (0.28
µ
V)
MOD:1kHz /
±
1.5kHz
2. Sensitivity
[Panel Test Mode]
Check
1) CH-Sig:1-1
Check
12dB SINAD or
SSG OUT
more
-117dBm (0.316
µ
V)
(MOD:1kHz /
±
1.5kHz)
3. Squelch
1) Adj item [SQL]
Adjust to point
(Preset)
Adjust [
∗∗∗
]
of opening
Adjust
SSG OUT:
squelch.
12dB SINAD level +2dB
2) Adj item
[L SQL]
➞
[C SQL]
➞
[H SQL]
Adjust [
∗∗∗
]