TK-280
18
REALIGNMENT
8-2. Channel Setting Mode
This is a mode for making channel settings with the panel
keys without using the FPU.
Pressing [MON] when [SELF PROG] is displayed, sets
Channel Setting Mode.
Select an item set with [D] and change the selection with the
encoder.
The data displayed with [C] is stored in the memory and
then proceeds to the next item. Pressing [D] proceeds to the
next item without storing it in the memory.
Press [MON] to set the display to [SELF PROG] and return
to reset (default) status.
Items set in Channel Setting Mode are as follows.
Function settings
Display
Remarks
Channel select Channnel
or Group
RX Frequency RXF
[CALL] : Freq. On/Off switching
[B] : 5kHz/6.25kHz/1MHz step
switching
RX Signalling RXS
[CALL] : OFF/QT/DQT switching
[B] : 1 step/Standard switching
[A] : DQT Normal/Invert swtiching
TX Frequency TXF
Key operation same as RX
Frequencies
TX Signalling TXS
Key operation same as RX
Signalling
Scan Delete/Add SCN
DEL/ADD
RF Power
PWR
HIGH/LOW
Beat Shift
SFT
YES/NO
Wide/Semi wide W/N
Wide/Semi wide/Narrow
/Narrow
Compander
CMP
ON/OFF
R134
TX-RX UNIT (X57-6192-70)
Foil Side
Fig. 3
8. Self Programming Mode
Write mode for frequency data and signalling etc. Mainly
used by the person maintaining the user equipment.
8-1. Enter to the self programming mode
Delete R134 (SELF, Figure 3) in the TX-RX unit and turn
the power switch on while pressing the [CALL] key. When enter
the self progrumming mode, “SELF PROG” is displayed.
Note :
This mode (self programming mode) cannot be set when it
has been disabled with the KPG-60D.
Fig. 2
6. Press the [D] key on the master while the master displays
"CLONE MODE". The data of the master is sent to the slave.
While the slave is receiving the data, "PROGRAM" is
displayed. When cloning of data is completed, the master
displays "END", and the slave automatically operates in
the User mode. The slave can then be operated by the
same program as the master.
7. The other slave can be continuously cloned. When the [D]
key on the master is pressed while the master displays
"END", the master displays "CLONE MODE". Carry out the
operation in step 4 to 6.
Note:
Only the same models can be cloned together.