19
TK-2107
TK-260
:K, K2
Required Test Equipment
1. Stabilized Power supply
1. The supply voltage can be changed between 5V and 18V,
and the current is 3A or more.
2. The standard voltage is 7.5V.
2. DC Ammeter
1. Class 1 ammeter (17 ranges and other features).
2. The full scale can be set to either 300mA or 3A.
3. A cable of less internal loss must be used.
3. Frequency Counter (f. counter)
1. Frequencies of up to 1GHz or so can be measured.
2. The sensitivity can be changed to 500MHz or below, and
measurements are highly stable and accurate (0.2ppm or
so).
4. Power Meter
1. Measurable frequency : Up to 500MHz
2. Impedance : 50
, unbalanced
3. Measuring range : Full scale of 10W or so
4. A standard cable (5D2W 1m) must be used.
5. RF Voltmeter(RF V.M)
1. Measurable frequency : Up to 500MHz or so.
6. Linear Detector
1. Measurable frequency : Up to 500MHz or so
2. Characteristics are flat, and CN is 60dB or more.
7. Digital Voltmeter
1. Voltage range : FS=18V or so
2. Input resistance : 1M
or more
ADJUSTMENT
8. Oscilloscope
1. Measuring range : DC to 30MHz
2. Provides highly accurate measurements for 5 to 25MHz.
9. AF Voltmeter (AF V.M)
1. Measurable frequency : 50Hz to 1MHz
2. Maximum sensitivity : 1mV or more
10. Spectrum Analyzer
1. Measuring range : DC to 1GHz or more
11. Standard Signal Generator (SSG)
1. Maximum frequency : 500MHz or more
2. Output : -133dBm/0.05
µ
V to 7dBm/501mV
3. Output impedance : 50
12. Tracking Generator
1. Center frequency : 50kHz to 500MHz
2. Frequency deviation :
±
35MHz
3. Output voltage : 100mV or more
13. Dummy Load
1. 8 , 3W or more
14. AF Generator(AG)
1. Frequency range : 100Hz to 100kHz
2. Output : 0.5mV to 1V
15. Distortion Meter
1. Measurable frequency : 30Hz to 100kHz
2. Input level : 50mV to 10Vrms
PTT switch
LED indicator
Monitor key
Power switch
Channel switch
SP/MIC JAC
Speaker
Antenna Microphone
• Use a non-conductive rod such as a Ceramic rod for
adjustment (especially of trimmers and coils).
Kenwood order No.
A-0910 (0.4X0.9mm)
Kenwood order No.
A-1310 (0.4X1.3mm)
• To protect the SSG,do not send out signals while adjusting
the receiving unit.
• The indicated SSG output levels are for maximum output.