3. INSTALLATION AND 

CONNECTION 

3-2.  C O N N E C T I O N 

NOTE 

The following instructions are for use by either 
your KENWOOD dealer, an authorized KENWOOD 
service facility, or the factory. 

WARNING 
Never connect AC power to the DC Power Supply 

until installation is complete. 

3-1.  I N S T A L L A T I O N 

CAUTIONS 
1. Prior to installation, check that the correct fuse 

is installed. 

2. Choose a location that is relatively free from 

vibration. 

3. Do not place the unit in a place which is 

exposed to direct sunlight, near a heater, etc. 

4. Do not store or use the unit in a dusty location 

or in a moist atmosphere. Select a well 
ventilated location. 

5. To maintain good ventilation: 

Remove the packing materials. 
Do not cover the unit. 
Place the unit at least 10 cm (4") away from 

the walls. 

6. (With the Europe and the General Markets 

version only) 

Prior to installation, check that the AC Voltage 

Selector on the side panel is set to the correct 

line voltage. 

A C  V O L T A G E  S E L E C T I O N 

With the Europe and General Markets version) 

CAUTION 
Make sure that the AC cable is disconnected 
before selecting an AC voltage. 

When changing an AC operating voltage, select the 
desired voltage with the selector switch located on 
the side cover. In this case, the correct fuse must 
be installed, referring to Section 5-4. FUSE 

REPLACEMENT. 

WARNING 

Never connect AC power to the DC Power Supply 
until installation is complete. 

CAUTIONS 
1. Before connecting or disconnecting the DC 

Power Cable, be sure to turn off the POWER 

switches of both the radio and the DC Power 
Supply. 

2. Observe polarity of the DC Power Cable. The 

radio operates on 13.8 VDC, negative ground. 

NOTES 
1. The DC Power Supply will not operate if the 

output terminals are shorted. 

2. The DC Power Supply may not operate if the 

POWER switch is turned on with the radio in 

transmit mode because the protection circuit 

may operate. 

1. Connect the DC Power Cable from the radio to 

the Output Terminals on the Rear Panel, as 
shown in Fig. 3-1.. 

Red lead -> Plus (+) Terminal 
Black lead -> Minus (—) Terminal 

2. Connect the AC power Cable to the AC outlet. 

NOTE 
Illustration shows the U.S.A. version. 

Fig.  3 - 1 . 

Black 

Fuse Holders 

To the Radio 

Red 

Output Terminals 

AC outlet 

Summary of Contents for PS-33

Page 1: ... PRINTED IN JAPAN B62 0142 10 K E M P T X MC 93 12 11 10 9 8 7 6 5 4 3 2 DC POWER SUPPLY PS 33 PS 53 INSTRUCTION MANUAL KENWOOD CORPORATION KENWOOD ...

Page 2: ...m Always remove the mains plug from the wall outlet prior to any maintenance of this equipment WARNING THIS EQUIPMENT MUST BE EARTHED IMPORTANT This plug contains a 13 ampere fuse Should the fuse need to be replaced ensure that the replacement fuse has a current rating of 13 amperes Use only fuses stamped with an ASTA or BSI approval mark on the body of the fuse If the moulded plug is incompatible...

Page 3: ...ll the power cord when disconnecting it from the AC wall outlet Grasp the plug and ensure that your fingers do not touch the live pins Do not place the unit in areas of excessive dust high humidity or on unstable surfaces To avoid risk of electric shock under no circumstances should the unit be opened If an abnormal odor or smoke is detected immediately turn the power off and pull out the power pl...

Page 4: ...50 duty cycle 20 5 A max Continuous operation for 1 hour Output voltage regulation Within 0 7 V at 120 220 230 240 VAC 10 variation with 16A Within 0 7 V at load current variation from 2 to 16A Ripple voltage Less than 20 mVrms at 13 8 VDC 16A Power consumption Approx 550 W at 13 8 VDC 22 5A Dimensions WXHXD Dimensions in include projections 173X96X296 mm 173X107X322 mm 6 13 16 X 3 25 32 X11 21 32...

Page 5: ...ts version CAUTION Make sure that the AC cable is disconnected before selecting an AC voltage When changing an AC operating voltage select the desired voltage with the selector switch located on the side cover In this case the correct fuse must be installed referring to Section 5 4 FUSE REPLACEMENT WARNING Never connect AC power to the DC Power Supply until installation is complete CAUTIONS 1 Befo...

Page 6: ...set at the factory and should only be readjusted by a qualified technician with proper test equipment Attempting service or adjustment without factory authorization can void the DC Power Supply s warranty If your DC Power Supply fails to work contact the authorized KENWOOD dealer from which you purchased it for quick reliable repair NOTES 1 When claiming warranty service please include a photocopy...

Page 7: ...CIRCUIT DIAGRAM SCHEMATIC DIAGRAM Q 1 Q 2 2 N 5 8 8 5 D 1 S 2 5 V B 1 0 D2 S L P 1 4 4 B Note Circuit is su t to change without notice due to advancement in technology ...

Page 8: ...1 Note Circuit is subjec change without notice due to advancement in technology 01 2 S A 5 2 CY 02 0 3 0 5 Z S C 2 4 5 8 CY Q4 2SB941 Q 0 1 5 8 t 1 S 1 5 5 5 02 3 J 0 S A 3 A 1 D 6 UZ9 1BL D7 UZ15BH T H 1 3 2 0 2 7 T H 2 5 T P 1 L ...

Page 9: ...AC F05 6021 05 6A Europe and General Market 120 VAC F05 6021 05 6A Europe and General Market 230 VAC F05 4024 05 4A U K 240 VAC F05 4024 05 4A Oceania 240 VAC F05 3022 05 3A NOTE Fuse Holder is located on rear panel for U S A version as Fig 4 2 Other version except for U S A version fuse holder is located inside of the top cover 5 5 SUPPLY CORD REPLACEMENT Oceania version only If the supply cord o...

Page 10: ...KENWOOD ...

Reviews: