1-20 (No.RA012<Rev.001>)
4.5
Common Section
*Note 1:
During test mode, click the [Tune Assist Voltage] button in test mode dialog box, then start automatic adjustment of the Receive/
Transmit assist voltage.
4.6
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Test-
equipment
Unit Terminal Unit Parts Method
1. Setting
1) Power supply voltage
DC power supply terminal : 7.5V
2. Receive
Assist voltage
1) Auto tuning
*Note 1
FPU
2.3 ± 0.1V
3. Transmit
Assist voltage
1) Auto tuning
*Note 1
FPU
2.3 ± 0.1V
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Test-
equipment
Unit Terminal Unit Parts
Method
1. Frequency
(1)TEST CH:
PTT ON
Frequency
counter
ANT
cable
FPU 446.128125MHz
±50Hz
2. Transmit
Power
(1)TEST CH:
(2)Baterry Terminal voltage:
7.5V
(3)PTT ON
Power
meter
Ammeter
ANT
cable
FPU 0.85W
±0.05W
0.7A or less
3. DQT
Balance 1
*Note 2
(1)TEST CH:
(2)Deviation meter filter
LPF: 3kHz
HPF: OFF
(3)PTT ON
Deviation
meter
Oscillo-
scope
ANT
cable
FPU Make the demodula-
tion wave into square
wave.
3. DQT
Balance 2
*Note 2
(1)TEST CH:
(2)Deviation meter filter
LPF: 3kHz
HPF: OFF
(3)PTT ON
Deviation
meter
Oscillo-
scope
ANT
cable
FPU The Deviation of
20Hz frequency is-
fixed.
Change the 1kHz ad-
justment value to be-
come the same
deviation of 20Hz
within the specified
range.
±15Hz
4. Maximum
Deviation
(Analog Nar-
row)
(1)TEST CH:
(2)Deviation meter filter
LPF: 15kHz
HPF: OFF
(3)PTT ON
Deviation
meter
Oscillo-
scope
ANT
cable
FPU 2.0kHz (According to
, -)
±50Hz
Note:
FPU auto in-
put 1kHz/
150mV
5. Maximum
Deviation
(dPMR Very
Narrow)
*Note 3
(1)TEST CH:
(2)Deviation meter filter
LPF: 15kHz
HPF: OFF
(3)PTT ON
Deviation
meter
Oscillo-
scope
ANT
cable
FPU 1.337kHz ±50Hz
6. DQT
Deviation
(Analog Nar-
row)
(1)TEST CH:
(2)Deviation meter filter
LPF: 3kHz
HPF: OFF
(3)PTT ON
Deviation
meter
Oscillo-
scope
ANT
cable
FPU 0.35kHz
±40Hz
7. QT Deviation
(Analog Nar-
row)
(1)TEST CH:
(2)Deviation meter filter
LPF: 3kHz
HPF: OFF
(3)PTT ON
Deviation
meter
Oscillo-
scope
ANT
cable
FPU 0.35kHz