1-54 (No.RA017<Rev.003>)
13.
Maxi-
mum
Devia-
tion
*2
[Analog
Wide]
1) Adj item: [ADEV]
Adjust:[****]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Maxmum Devia-
tion (Analog Wide)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value for
each adjustment point.
(The value is written be-
low.) Transmit at each
adjustment point and
check that the deviation
is between 4150Hz and
4250Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
505 (F,K)
503 (F2,K2)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
4150~4250Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
[Analog
Narrow]
1) Adj item:
[An ADEV]
Adjust:[****]
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Maxmum Devia-
tion (Analog Nar-
row)]
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value for
each adjustment point.
(The value is written be-
low.) Transmit at each
adjustment point and
check that the deviation
is between 2050Hz and
2150Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
505 (F,K)
499 (F2,K2)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2050~2150Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
*2 : Refer to the “4.9.1 Necessary Deviation adjustment item for each signaling and mode” table.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method