1-14 (No.RA017<Rev.003>)
2.3.2.1
Installing the KAP-2 unit in the transceiver
(The kit A is not used in the KAP-2 accessories)
(1) Remove the cabinet, top packing and shielding plate of the
transceiver.
(2) Set the KAP-2 relay unit jumper pins according to the pur-
pose of use.
(3) Remove the 6-pin jumper connector inserted in the TXRX
unit (A/2) connector (CN910). <1>
Fig.2-1
(4) Insert one side of the lead wire with connector (E37-1114-
05) into the relay unit connector (CN3) <2> and the other
side into the TX-RX unit (A/2) connector (CN910) <3>
Fig.2-2
(5) Place the relay unit at the position shown in Figure 2-2 and
secure it to the chassis with a screw.
(6) Remove the cap on the rear of the chassis by pushing it
from the inside with your finger. <4>
Fig.2-3
(7) Pass the 6-pin connector of the cable (E37-1113-25)
through the chassis hole <5> and insert the bush into the
shassis hole.
(8) Rotate the bush of the cable 90 degrees counterclockwise
as viewed from the rear of the chassis. <6>
(9) Insert the 6-pin connector of the cable into the connector
(CN2) of the KAP-2 relay unit. <7>
Note:
You must setup using the KPG-D1/D1N.
Fig.2-4
(10) Form the KAP-2 cable as shown in the figure.
CN910
<1>
CN910
CN3
E37-1114-05
<2>
<3>
<4>
<5>
E37-1113-25
CN2
<7>
<6>
<6>
<6>
KAP-2 cable