Test Channel
No.
RX
TX
1
155.050000MHz
155.100000MHz
2
136.050000MHz
136.100000MHz
3
173.950000MHz
173.900000MHz
4
155.000000MHz
155.000000MHz
5
155.200000MHz
155.200000MHz
6
155.400000MHz
155.400000MHz
7~16
Blank
Blank
ADJUSTMENT
Test Signaling (Analog)
No.
RX (Decode Signaling)
TX (Encode Signaling)
1
None
None
2
None
100Hz Square Wave
3
QT 67.0Hz
QT 67.0Hz
4
QT 151.4Hz
QT 151.4Hz
5
QT 210.7Hz
QT 210.7Hz
6
QT 254.1Hz
QT 254.1Hz
7
DQT D023N
DQT D023N
8
DQT D754I
DQT D754I
9
None
CWID Encode (ID: VVV)
10
None
Single Tone
11
DTMF Decode (CODE: 159D) DTMF Encode (CODE: 159D)
12
None
DTMF Encode (CODE: 9)
13
None
Courtesy Tone
Test Signaling (NXDN)
No.
RX (Decode Signaling)
TX (Encode Signaling)
1
RAN 1
RAN 1
2
RAN 1
PN 9
3
RAN 1
Maximum Deviation Pattern
• Signaling number 1 is used for link test.
• Signaling number 2 is used for TX modulation signal qual-
ity test. i.e, TX adjacent channel power, FSK error, Occu-
pied bandwidth, Emission mask, etc.
• Signaling number 3 is used for TX deviation test. If the
modulation mode is very narrow, the modulation fre-
quency is 600Hz. If the modulation mode is narrow, the
modulation frequency is 1200Hz.
Adjustment Points
RX_CV
RX_AST
2nd_Lo
LDT
MB
MB_CV2
MO
TX_AST
TX_CV
LDR
450kHz
ASWC
MOD
VOUT4
VOUT7
TX-RX UNIT
Component side