NXR-700
36
Pin No.
Name
I/O
Function
4
GND
-
Ground
5
D_GND
-
Ground
6
SDA
I/O EEPROM Data
7
D_GND
-
Ground
8
SCK
O
EEPROM Clock
9
D_GND
-
Ground
10
CONT_5.0V
O
Switched 5V power supply
11
D_GND
-
Ground
12
TEMP_PRT
I
Temp protection signal input
13
GND
-
Ground
14
ANT_SW
O
TX anntena switch output
15
GND
-
Ground
16
TEMP_RST
O
Tempereture sensor reset signal output
17
GND
-
Ground
18
FAN_CONT2
O
FAN2 control signal output
19
GND
-
Ground
20
FAN_CONT
O
FAN1 control signal output
21
GND
-
Ground
22
PWR_CONT
O
Power control signal output
23
GND
-
Ground
24
PWR_PRT
O
Power protection signal output
25
GND
-
Ground
26
RFL_PWR
I
Refl ect power signal input
27
GND
-
Ground
28
FWD_PWR
I
Forward power signal input
29
GND
-
Ground
30
FAN_CURR
I
Fan current monitor signal input
31
GND
-
Ground
32
PA_CURR
I
PA current monitor signal input
33
GND
-
Ground
34
NC
-
No connection
35
GND
-
Ground
36
GND
-
Ground
CN807 (To X42-328 CN3: OCXO Optional unit)
1
8OCXO
O
OCXO power supply 8V
2
GND
-
Ground
TX Unit (X56-3112-72) (B/3)
Pin No.
Name
I/O
Function
CN920 (To X56-311 C/3 CN960)
1
DC8
O
8V Power supply
2
GND
-
Ground
Pin No.
Name
I/O
Function
3
50MPU
O
Switched 5V power supply
4
STB
O
Shift Register Strobe
5
SR_OE
O
Shift Register Output Enable
6
SR_CLK
O
Shift Register Clock
7
SR_DATA
O
Shift Register Data
8
LED1
O
D960 segment “F” control
9
GND
-
Ground
10
LED10
O
D961 segment “F” control
CN921 (To X53-413 CN3)
1
MIG
-
MIC Ground
2
GND
-
Ground
3
MIC
O
MIC Signal Input
4
33MPU
I
Switched 3.3V power supply
5
33AUD
I
Switched 3.3V power supply
6
VOLUME_IN
O
Volume control output for AF signal
7
SB
I
Power supply output
8
OCXO_ST_R
I
OCXO Red LED Switch
9
PWR_ST_R
I
POWER Red LED Switch
10
OCXO_ST_G
I
OCXO Green LED Switch
11
GND
-
Ground
12
HOOK_RXD_SCM
O
HOOK detect signal
13
SCM_EN
-
No connection
14
PTT_TXD_SCM
O
MIC PTT
15
GND
-
Ground
16
SR_OE
I
Shift Register Output Enable
17
GND
-
Ground
18
SR_CLK
I
Shift Register Clock
19
GND
-
Ground
20
SR_DATA
I
Shift Register Data
21
GND
-
Ground
22
STB1
I
Shift Register Strobe
23
GND
-
Ground
24
K1
O
Key Scan
25
K2
O
Key Scan
26
K3
O
Key Scan
27
K4
I
Key Scan
28
K5
I
Key Scan
29
DC8
I
8V Power supply
30
GND
-
Ground
31
50MPU
I
Switched 5V power supply
32
50MPU
I
Switched 5V power supply
33
DC8
I
8V Power supply
TERMINAL FUNCTION
Summary of Contents for NEXEDGE NXR-700
Page 110: ...NXR 700 110 MEMO ...
Page 119: ...NXR 700 117 MEMO ...
Page 137: ...NXR 700 135 MEMO ...
Page 138: ...NXR 700 136 MEMO ...
Page 140: ...NXR 700 ...
Page 171: ...1 E CN300 RX_IF_VN ...