IMPORTANT: All intervention regarding installation maintenance and conversion of
the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
MAINTENANCE AND CONVERSION TO NATURAL GAS OR TO LPG
Table for the Choice of the Injectors Cat: II 2H3+
GB
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 (28-30 mbar)
G31 (37 mbar)
Natural Gas
G20 (20 mbar)
Ø injector
[1/100
mm]
Ring
opening
[mm]
Ø injector
[1/100
mm]
Ring
opening
[mm]
Oven
2,70
0,65
78
Fully
open (*)
120
2 (*)
(*) = Reference value
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Oven
5,40