TEST MODE
11. Method of the span switching (K and M type only)
While holding the Preset 1 and Preset 5 keys, reset the
unit.
12. Other specifications
• No displays such as "CODE OFF" during Power-ON.
• Pressing the TI (AUTO) key during changer operation
turns on 2zone. Cancel by pressing the TI (AUTO) key
again. The P/S dot is lit during 2zone.
• In the case of 2 PREOUT model with Non Fader output,
• In the case of 2 colors key illumination model, Each press
the ATT key during All OFF, the key illumination is
switching Green or Red.
■
Security-related information
1. Forced Power ON mode (All models)
Even when the security (Cord) is approved, resetting the
unit while holding the ATT and Preset 4 keys makes it
possible to turn the power ON for 30 minutes.
After 30 minutes have elapsed, it is not possible to return
to the previous condition unless the unit is reset again.
2. Method of registration of the security code after
EEPROM (Tuner Unit Ass'y) replacement (Code
security model)
1. Enter the test mode. (See 1. How to enter the test mode)
2. Press the PLAY/PAUSE key to enter the Menu mode.
3. When the message "Security" is displayed, press and
hold the Track Up/Down key for 1 second to enter the
security registration mode.
4. Enter the code using the FM/AM/Track Up/Track Down
keys.
• FM key
: Number up
• AM key
: Number down
• Track Up key
: Cursor right shift
• Track Down key
: Cursor left shift
5. Hold down the Track Up key for at least 3 seconds and
the message, "RE-ENTER" appears, so once again enter
the code according to Step 4 above.
6. Press and hold the Track Up key for 3 seconds until
"APPROVED" is displayed.
7. Exit from the test mode. (See 2. How to exit from the test
mode)
(Note) All Clear is not applicable to the security code of
this model.
3. Simple way to clear the security code (K type only)
1. During code request mode, press the VOL UP key for at
least 3 seconds while holding down the DISP key. (----
will disappear)
2. Enter, "KCAR" with the remote controller as described
below. (Same as on 01 model.)
• Press the remote controller 5 key twice, and press the
Track Up key. (Enters a "K")
• Press the remote controller 2 key three times, and press
the Track Up key. (Enters a "C")
• Press the remote controller 2 key once, and press the
Track Up key. (Enters an "A")
• Press the remote controller 7 key twice, and press the
Track Up key. (Enters an "R")
3. Security function is canceled and unit sets to All-Off mode.
4. Code request mode appears if a mistake was made in
entering the numbers.
10. Special display when the display is all on
Pressing the Preset keys while the power is ALL OFF
displays the following information.
PRESET 1
Version display (8 digits, Month/Day/Hour/Minute)
(Display) SYS xxxxxxxx : System microcomputer
PAN xxxxxxxx : Panel microcomputer
PRESET 2
Sireal number display (8 digits)
(Display) SNo xxxxxxxx
z
PRESET 3
Short press : View power ON time.
(The All OFF period is not counted.)
Long press/hold : Clear power ON time at
the power ON time displaying.
(Display) PonTim xxxxx Max. 65535 (hours)
PRESET 4
Short press : Display CD operation time.
Long press/hold : Clear CD operation time at
the CD operation time displaying.
(Display) CDTime xxxxx Max. 65535 (hours)
PRESET 5
Short press : Display CD ejection count.
Long press/hold : Clear CD ejection count at
the CD ejection count displaying.
(Display) EjeCnt xxxxx
Max. 65535 (times)
PRESET 6
Short press : Display Panel open/close count.
Long press/hold : Clear Panel open/close
count at the Panel open/close count.
(Display) PnCnt xxxxxx
Max. 655350 (times)